Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
251
matching recommendationsSIC | 3211 | Flat Glass |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0190 # 06 Y:2004 | 06 | 2004 | USE PHOTOCELL CONTROLS | $846 | $90 | Implemented |
LL0190 # 07 Y:2004 | 07 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $635 | $240 | Implemented |
LL0190 # 08 Y:2004 | 08 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $411 | $350 | Implemented |
LL0190 # 09 Y:2004 | 09 | 2004 | INSTALL OCCUPANCY SENSORS | $389 | $120 | Implemented |
LL0190 # 10 Y:2004 | 10 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $2,500 | $60 | Implemented |
OK0605 # 01 Y:2000 | 01 | 2000 | LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE | $6,168,500 | $723,000 | Not Implemented |
OK0605 # 02 Y:2000 | 02 | 2000 | IMPROVE COMBUSTION CONTROL CAPABILITY | $606,630 | $500,000 | Not Implemented |
OK0605 # 03 Y:2000 | 03 | 2000 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $606,250 | $3,000,000 | Not Implemented |
OK0605 # 04 Y:2000 | 04 | 2000 | MODIFY WORKLOAD | $1,214,000 | $850,000 | Not Implemented |
OK0605 # 05 Y:2000 | 05 | 2000 | INSTALL AUTOMATIC PACKING EQUIPMENT | $232,800 | $280,000 | Not Implemented |
OK0605 # 06 Y:2000 | 06 | 2000 | PURCHASE MATERIAL FROM SUPPLIER IN CUSTOMIZED PACKAGING | $528,240 | $500,000 | Not Implemented |
OK0605 # 07 Y:2000 | 07 | 2000 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $5,473,600 | $4,750,000 | Not Implemented |
OK0605 # 08 Y:2000 | 08 | 2000 | MODIFY WORKLOAD | $958,400 | $500,000 | Not Implemented |
GT0676 # 01 Y:1999 | 01 | 1999 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $3,081 | $500 | Not Implemented |
GT0676 # 02 Y:1999 | 02 | 1999 | RECOVER AND REUSE WASTE MATERIAL | $11,148 | $0 | Implemented |
GT0676 # 03 Y:1999 | 03 | 1999 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $29,047 | $12,000 | Not Implemented |
GT0676 # 04 Y:1999 | 04 | 1999 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $20,293 | $15,000 | Not Implemented |
GT0676 # 05 Y:1999 | 05 | 1999 | IMPROVE SPACE COMFORT CONDITIONING | $33,650 | $18,000 | Not Implemented |
GT0676 # 06 Y:1999 | 06 | 1999 | COMBINE UTILITY METERS | $292 | $0 | Not Implemented |
GT0676 # 07 Y:1999 | 07 | 1999 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $1,295 | $100 | Not Implemented |
GT0676 # 08 Y:1999 | 08 | 1999 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $16,324 | $35,000 | Not Implemented |
WV0167 # 01 Y:1999 | 01 | 1999 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $12,173 | $1,000 | Implemented |
WV0167 # 02 Y:1999 | 02 | 1999 | INSTALL OCCUPANCY SENSORS | $809 | $315 | Not Implemented |
WV0167 # 03 Y:1999 | 03 | 1999 | INSULATE BARE EQUIPMENT | $5,901 | $606 | Implemented |
WV0167 # 04 Y:1999 | 04 | 1999 | BURN A LESS EXPENSIVE GRADE OF FUEL | $22,359 | $12,500 | Not Implemented |