Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
207
matching recommendationsSIC | 322 | Glass And Glassware, Pressed Or Blown |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0396 # 04 Y:2015 | 04 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $214 | $105 | Implemented |
LE0396 # 03 Y:2015 | 03 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,080 | $2,845 | Implemented |
LE0396 # 01 Y:2015 | 01 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $702 | $35 | Implemented |
UD0923 # 07 Y:2015 | 07 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $14,734 | $0 | Implemented |
UD0923 # 08 Y:2015 | 08 | 2015 | DEVELOP A REPAIR/REPLACE POLICY | $5,978 | $19,581 | Implemented |
UD0923 # 10 Y:2015 | 10 | 2015 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $343 | $0 | Implemented |
UD0923 # 01 Y:2015 | 01 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,241 | $50 | Implemented |
MZ0145 # 09 Y:2014 | 09 | 2014 | USE PHOTOCELL CONTROLS | $1,686 | $2,450 | Implemented |
MZ0145 # 08 Y:2014 | 08 | 2014 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,868 | $0 | Implemented |
MZ0145 # 07 Y:2014 | 07 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,268 | $0 | Implemented |
MZ0145 # 06 Y:2014 | 06 | 2014 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $17,814 | $30,000 | Implemented |
MZ0145 # 04 Y:2014 | 04 | 2014 | UPGRADE CONTROLS ON COMPRESSORS | $113,101 | $200,000 | Implemented |
MZ0145 # 03 Y:2014 | 03 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $192,210 | $220,000 | Implemented |
MZ0145 # 02 Y:2014 | 02 | 2014 | INSULATE BARE EQUIPMENT | $105,420 | $300,000 | Implemented |
MAS031 # 05 Y:2012 | 05 | 2012 | INSULATE BARE EQUIPMENT | $593 | $425 | Implemented |
MAS031 # 02 Y:2012 | 02 | 2012 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $13,552 | $150 | Implemented |
UW0028 # 08 Y:2009 | 08 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $144 | $0 | Implemented |
UW0028 # 06 Y:2009 | 06 | 2009 | METER WASTE WATER | $1,060 | $12,000 | Implemented |
UW0028 # 04 Y:2009 | 04 | 2009 | INSTALL OCCUPANCY SENSORS | $12,524 | $1,960 | Implemented |
UW0028 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,942 | $76,700 | Implemented |
MA0618 # 03 Y:2007 | 03 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $12,316 | $3,220 | Implemented |
MA0618 # 04 Y:2007 | 04 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,204 | $29,875 | Implemented |
MA0618 # 02 Y:2007 | 02 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $32,820 | $26,621 | Implemented |
MA0618 # 09 Y:2007 | 09 | 2007 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $1,070 | $340 | Implemented |
MA0618 # 08 Y:2007 | 08 | 2007 | INSTALL TIMERS AND/OR THERMOSTATS | $4,125 | $3,552 | Implemented |