Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
281
matching recommendationsSIC | 3295 | Minerals, Ground Or Treated |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NV0083 # 04 Y:1997 | 04 | 1997 | USE PHOTOCELL CONTROLS | $1,309 | $470 | Not Implemented |
NV0083 # 05 Y:1997 | 05 | 1997 | INSTALL OCCUPANCY SENSORS | $333 | $164 | Not Implemented |
NV0083 # 06 Y:1997 | 06 | 1997 | INSULATE BARE EQUIPMENT | $4,110 | $4,316 | Not Implemented |
NV0083 # 07 Y:1997 | 07 | 1997 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $0 | $0 | Not Implemented |
MS0083 # 01 Y:1997 | 01 | 1997 | USE SYNTHETIC LUBRICANT | $2,061 | $200 | Not Implemented |
MS0083 # 02 Y:1997 | 02 | 1997 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $118,026 | $75,928 | Not Implemented |
MS0083 # 03 Y:1997 | 03 | 1997 | INSULATE BARE EQUIPMENT | $9,737 | $12,878 | Implemented |
MS0083 # 04 Y:1997 | 04 | 1997 | BURN WASTE OIL FOR HEAT | $1,022 | $1,995 | Not Implemented |
MS0083 # 05 Y:1997 | 05 | 1997 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $480,511 | $9,400 | Not Implemented |
WV0094 # 01 Y:1996 | 01 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $450 | $640 | Implemented |
WV0094 # 02 Y:1996 | 02 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,654 | $42 | Implemented |
WV0094 # 03 Y:1996 | 03 | 1996 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $14,094 | $8,910 | Not Implemented |
WV0094 # 04 Y:1996 | 04 | 1996 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,561 | $968 | Not Implemented |
WV0094 # 05 Y:1996 | 05 | 1996 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,367 | $4,500 | Not Implemented |
WV0094 # 06 Y:1996 | 06 | 1996 | USE PLASTIC PALLETS INSTEAD OF WOOD | $11,520 | $5,784 | Not Implemented |
WV0094 # 07 Y:1996 | 07 | 1996 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $13,272 | $7,000 | Implemented |
GT0562 # 01 Y:1995 | 01 | 1995 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $82,460 | $0 | Implemented |
GT0562 # 02 Y:1995 | 02 | 1995 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $67,980 | $0 | Implemented |
GT0561 # 01 Y:1995 | 01 | 1995 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $473,300 | $1,050,000 | Implemented |
GT0561 # 02 Y:1995 | 02 | 1995 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $166,370 | $235,000 | Not Implemented |
GT0561 # 03 Y:1995 | 03 | 1995 | CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS | $99,420 | $0 | Not Implemented |
GT0561 # 04 Y:1995 | 04 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,950 | $4,550 | Implemented |
GT0561 # 05 Y:1995 | 05 | 1995 | USE SCREENING, MAGNETIC SEPARATION TO REMOVE CONTAMINANTS | $349,805 | $1,000,000 | Not Implemented |
GT0561 # 06 Y:1995 | 06 | 1995 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $45,730 | $201,600 | Implemented |
MO0122 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $19,322 | $44,473 | Implemented |