Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
772
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0296 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,364 | $9,710 | Implemented |
BD0296 # 03 Y:2005 | 03 | 2005 | USE PHOTOCELL CONTROLS | $2,773 | $1,800 | Implemented |
BD0296 # 04 Y:2005 | 04 | 2005 | INSTALL SKYLIGHTS | $1,813 | $1,472 | Implemented |
BD0296 # 05 Y:2005 | 05 | 2005 | INSTALL OCCUPANCY SENSORS | $1,793 | $1,425 | Implemented |
BD0296 # 06 Y:2005 | 06 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,160 | $600 | Implemented |
BD0296 # 07 Y:2005 | 07 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $924 | $500 | Not Implemented |
BD0296 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $846 | $650 | Implemented |
BD0296 # 09 Y:2005 | 09 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $499 | $0 | Not Implemented |
BD0296 # 10 Y:2005 | 10 | 2005 | USE AN ALTERNATIVE DESULFURIZING AGENT TO ELIMINATE HAZARDOUS SLAG FORMATION | $192,926 | $3,000 | Implemented |
IC0082 # 01 Y:2004 | 01 | 2004 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $158,811 | $0 | Implemented |
IC0082 # 02 Y:2004 | 02 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $212,513 | $1,533 | Not Implemented |
IC0082 # 03 Y:2004 | 03 | 2004 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $295,385 | $90,783 | Implemented |
IC0082 # 04 Y:2004 | 04 | 2004 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $54,932 | $8,421 | Implemented |
IC0082 # 05 Y:2004 | 05 | 2004 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $7,283 | $1,450 | Implemented |
IC0082 # 06 Y:2004 | 06 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $24,495 | $470,000 | Not Implemented |
IC0082 # 07 Y:2004 | 07 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $311 | $282,150 | Implemented |
IC0082 # 08 Y:2004 | 08 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $516 | $600,000 | Not Implemented |
IC0086 # 01 Y:2004 | 01 | 2004 | ADJUST BURNERS FOR EFFICIENT OPERATION | $59,927 | $0 | Implemented |
IC0086 # 02 Y:2004 | 02 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,538 | $0 | Implemented |
IC0086 # 03 Y:2004 | 03 | 2004 | REPAIR AND ELIMINATE STEAM LEAKS | $4,044 | $3,000 | Implemented |
IC0086 # 04 Y:2004 | 04 | 2004 | INSTALL TIMERS AND/OR THERMOSTATS | $7,600 | $2,220 | Not Implemented |
IC0086 # 05 Y:2004 | 05 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,099 | $2,050 | Implemented |
IC0086 # 06 Y:2004 | 06 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $21,738 | $43,650 | Implemented |
IC0086 # 07 Y:2004 | 07 | 2004 | UPGRADE CONTROLS ON COMPRESSORS | $9,924 | $1,130 | Not Implemented |
IC0086 # 08 Y:2004 | 08 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,905 | $2,900 | Implemented |