Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
10,364
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0448 # 10 Y:2011 | 10 | 2011 | INSULATE BARE EQUIPMENT | $5,708 | $4,205 | Not Implemented |
UF0448 # 11 Y:2011 | 11 | 2011 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $291 | $1,730 | Not Implemented |
UF0448 # 12 Y:2011 | 12 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $515,044 | $294,885 | Not Implemented |
NC0439 # 01 Y:2011 | 01 | 2011 | USE RADIANT HEATER FOR SPOT HEATING | $37,298 | $27,675 | Not Implemented |
NC0439 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $22,669 | $39,646 | Implemented |
NC0439 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $330 | $106 | Implemented |
NC0439 # 04 Y:2011 | 04 | 2011 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $3,390 | $4,200 | Implemented |
NC0439 # 05 Y:2011 | 05 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $4,934 | $2,393 | Implemented |
NC0439 # 06 Y:2011 | 06 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,486 | $1,800 | Not Implemented |
NC0439 # 07 Y:2011 | 07 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,953 | $100 | Implemented |
MA0678 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $27,383 | $88,700 | Implemented |
MA0678 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $21,204 | $5,760 | Implemented |
MA0678 # 03 Y:2011 | 03 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,343 | $0 | Implemented |
MA0678 # 04 Y:2011 | 04 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,186 | $0 | Implemented |
MA0678 # 05 Y:2011 | 05 | 2011 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $6,819 | $26,495 | Not Implemented |
MA0678 # 06 Y:2011 | 06 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,833 | $8,590 | Not Implemented |
WV0436 # 01 Y:2011 | 01 | 2011 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $62,911 | $74,268 | Not Implemented |
WV0436 # 02 Y:2011 | 02 | 2011 | OPTIMIZE PLANT POWER FACTOR | $32,243 | $22,700 | Not Implemented |
WV0436 # 03 Y:2011 | 03 | 2011 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $21,604 | $29,900 | Not Implemented |
WV0436 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,837 | $45,545 | Implemented |
WV0436 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,983 | $8,375 | Not Implemented |
WV0436 # 06 Y:2011 | 06 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $9,039 | $1,920 | Not Implemented |
WV0436 # 07 Y:2011 | 07 | 2011 | USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER | $7,082 | $25,000 | Not Implemented |
WV0436 # 08 Y:2011 | 08 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,227 | $12,576 | Implemented |
WV0436 # 09 Y:2011 | 09 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $4,976 | $5,400 | Not Implemented |