Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
748
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LM0045 # 03 Y:2002 | 03 | 2002 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,903 | $0 | Implemented |
LM0045 # 04 Y:2002 | 04 | 2002 | USE EVAPORATION TO CONCENTRATE MATERIAL | $3,478 | $5,500 | Implemented |
LM0045 # 05 Y:2002 | 05 | 2002 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $37,050 | $11,250 | Implemented |
LM0045 # 06 Y:2002 | 06 | 2002 | ADVERTISE PRODUCT OR SERVICE | $198,750 | $2,000 | Not Implemented |
LM0045 # 07 Y:2002 | 07 | 2002 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $176,517 | $2,000 | Not Implemented |
SD0300 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,870 | $520 | Implemented |
SD0300 # 02 Y:2002 | 02 | 2002 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $9,208 | $20,000 | Not Implemented |
SD0300 # 03 Y:2002 | 03 | 2002 | USE PHOTOCELL CONTROLS | $8,501 | $9,000 | Not Implemented |
SD0300 # 04 Y:2002 | 04 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,056 | $14,800 | Not Implemented |
SD0300 # 05 Y:2002 | 05 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,105 | $0 | Not Implemented |
SD0300 # 06 Y:2002 | 06 | 2002 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $5,500 | $10,000 | Implemented |
SD0300 # 07 Y:2002 | 07 | 2002 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $11,000 | $0 | Not Implemented |
SD0300 # 08 Y:2002 | 08 | 2002 | INCREASE USE OF AUTOMATION | $42,640 | $20,000 | Not Implemented |
SD0300 # 09 Y:2002 | 09 | 2002 | INCREASE USE OF AUTOMATION | $2,296 | $3,500 | Not Implemented |
SD0300 # 10 Y:2002 | 10 | 2002 | PAY UTILITY BILLS ON TIME | $426 | $0 | Not Implemented |
LM0037 # 01 Y:2002 | 01 | 2002 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,266 | $1,050 | Not Implemented |
LM0037 # 02 Y:2002 | 02 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,665 | $2,150 | Not Implemented |
LM0037 # 03 Y:2002 | 03 | 2002 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $8,259 | $1,700 | Implemented |
LM0037 # 04 Y:2002 | 04 | 2002 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $24,595 | $27,000 | Not Implemented |
LM0037 # 05 Y:2002 | 05 | 2002 | USE OPTIMUM THICKNESS INSULATION | $1,908 | $306 | Not Implemented |
LM0037 # 06 Y:2002 | 06 | 2002 | INSULATE BARE EQUIPMENT | $755 | $224 | Not Implemented |
LM0037 # 07 Y:2002 | 07 | 2002 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $45,000 | $40,000 | Not Implemented |
LM0037 # 08 Y:2002 | 08 | 2002 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $17,066 | $14,227 | Not Implemented |
LM0035 # 01 Y:2002 | 01 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,856 | $968 | Implemented |
LM0035 # 02 Y:2002 | 02 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,044 | $2,500 | Implemented |