Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
10,364
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0749 # 13 Y:2006 | 13 | 2006 | USE MINIMUM SAFE OVEN VENTILATION | $4,400 | $0 | Implemented |
WV0347 # 01 Y:2006 | 01 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $255,013 | $57,159 | Implemented |
WV0347 # 02 Y:2006 | 02 | 2006 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $32,512 | $24,300 | Not Implemented |
WV0347 # 03 Y:2006 | 03 | 2006 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $11,796 | $1,000 | Implemented |
WV0347 # 04 Y:2006 | 04 | 2006 | DEVELOP A REPAIR/REPLACE POLICY | $10,908 | $504 | Implemented |
WV0347 # 05 Y:2006 | 05 | 2006 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $10,012 | $13,815 | Not Implemented |
WV0347 # 06 Y:2006 | 06 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $6,834 | $250 | Not Implemented |
WV0347 # 07 Y:2006 | 07 | 2006 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $5,696 | $10,600 | Not Implemented |
WV0347 # 08 Y:2006 | 08 | 2006 | USE RADIANT HEATER FOR SPOT HEATING | $5,557 | $2,790 | Implemented |
WV0347 # 09 Y:2006 | 09 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,051 | $65 | Implemented |
WV0347 # 10 Y:2006 | 10 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $915 | $245 | Not Implemented |
WV0347 # 11 Y:2006 | 11 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $457 | $158 | Not Implemented |
UM0307 # 01 Y:2006 | 01 | 2006 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $302,929 | $70,000 | Implemented |
UM0307 # 02 Y:2006 | 02 | 2006 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $219,438 | $0 | Not Implemented |
UM0307 # 03 Y:2006 | 03 | 2006 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $63,131 | $0 | Implemented |
UM0307 # 04 Y:2006 | 04 | 2006 | ADJUST BURNERS FOR EFFICIENT OPERATION | $55,043 | $2,400 | Implemented |
UM0307 # 05 Y:2006 | 05 | 2006 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $19,061 | $5,066 | Implemented |
UM0307 # 06 Y:2006 | 06 | 2006 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $14,621 | $1,500 | Implemented |
UM0307 # 07 Y:2006 | 07 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,914 | $5,000 | Not Implemented |
UM0307 # 08 Y:2006 | 08 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $10,428 | $2,000 | Implemented |
UM0307 # 09 Y:2006 | 09 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,814 | $10,054 | Implemented |
UM0307 # 10 Y:2006 | 10 | 2006 | INSULATE BARE EQUIPMENT | $3,606 | $1,191 | Implemented |
UM0307 # 11 Y:2006 | 11 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,358 | $2,100 | Not Implemented |
UM0307 # 12 Y:2006 | 12 | 2006 | INSULATE BARE EQUIPMENT | $3,085 | $0 | Implemented |
UM0307 # 13 Y:2006 | 13 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $754 | $75 | Implemented |