Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
545
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0222 # 02 Y:1994 | 02 | 1994 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,300 | $1,400 | Implemented |
AM0222 # 03 Y:1994 | 03 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,400 | $740 | Implemented |
AM0222 # 04 Y:1994 | 04 | 1994 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,470 | $0 | Not Implemented |
AM0222 # 05 Y:1994 | 05 | 1994 | INSTALL SKYLIGHTS | $1,580 | $1,000 | Implemented |
AM0222 # 06 Y:1994 | 06 | 1994 | PAY UTILITY BILLS ON TIME | $722 | $0 | Implemented |
AM0222 # 07 Y:1994 | 07 | 1994 | INSULATE BARE EQUIPMENT | $540 | $150 | Implemented |
AM0221 # 01 Y:1994 | 01 | 1994 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $58,720 | $80,000 | Not Implemented |
AM0221 # 02 Y:1994 | 02 | 1994 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $9,930 | $0 | Not Implemented |
AM0221 # 03 Y:1994 | 03 | 1994 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $5,430 | $0 | Implemented |
AM0221 # 04 Y:1994 | 04 | 1994 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,180 | $200 | Implemented |
AM0221 # 05 Y:1994 | 05 | 1994 | RECYCLE CASTING SAND | $37,570 | $0 | Implemented |
AM0221 # 06 Y:1994 | 06 | 1994 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $1,040 | $2,400 | Not Implemented |
AM0221 # 07 Y:1994 | 07 | 1994 | RECYCLE CASTING SAND | $63,410 | $209,930 | Not Implemented |
AM0214 # 01 Y:1994 | 01 | 1994 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $10,770 | $200,000 | Not Implemented |
AM0214 # 02 Y:1994 | 02 | 1994 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,160 | $540 | Not Implemented |
AM0214 # 03 Y:1994 | 03 | 1994 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $5,350 | $300 | Not Implemented |
AM0214 # 04 Y:1994 | 04 | 1994 | USE OPTIMUM TEMPERATURE | $790 | $1,000 | Not Implemented |
AM0214 # 05 Y:1994 | 05 | 1994 | ADJUST BURNERS FOR EFFICIENT OPERATION | $450 | $680 | Implemented |
AM0214 # 06 Y:1994 | 06 | 1994 | INSULATE BARE EQUIPMENT | $300 | $0 | Not Implemented |
AM0199 # 01 Y:1994 | 01 | 1994 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $16,380 | $3,700 | Implemented |
AM0199 # 02 Y:1994 | 02 | 1994 | USE SYNTHETIC LUBRICANT | $1,590 | $0 | Not Implemented |
AM0199 # 03 Y:1994 | 03 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,190 | $1,874 | Implemented |
AM0199 # 04 Y:1994 | 04 | 1994 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,410 | $70 | Implemented |
AM0199 # 05 Y:1994 | 05 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,570 | $2,055 | Implemented |
AM0199 # 06 Y:1994 | 06 | 1994 | USE SYNTHETIC LUBRICANT | $670 | $0 | Not Implemented |