Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
10,549
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0533 # 06 Y:1997 | 06 | 1997 | INSTALL OCCUPANCY SENSORS | $390 | $660 | Not Implemented |
AS0212 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,076 | $13,917 | Not Implemented |
AS0212 # 02 Y:1997 | 02 | 1997 | INSTALL OCCUPANCY SENSORS | $1,611 | $2,475 | Not Implemented |
AS0212 # 03 Y:1997 | 03 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,975 | $24,800 | Implemented |
AS0212 # 04 Y:1997 | 04 | 1997 | USE SYNTHETIC LUBRICANT | $878 | $800 | Implemented |
AS0212 # 05 Y:1997 | 05 | 1997 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $2,536 | $4,800 | Implemented |
AS0212 # 06 Y:1997 | 06 | 1997 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,877 | $0 | Implemented |
AS0212 # 07 Y:1997 | 07 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,979 | $8,806 | Not Implemented |
AS0212 # 08 Y:1997 | 08 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $53,109 | $64,120 | Not Implemented |
AS0212 # 09 Y:1997 | 09 | 1997 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $432 | $60 | Implemented |
AS0212 # 10 Y:1997 | 10 | 1997 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $4,320 | $120 | Not Implemented |
AS0212 # 11 Y:1997 | 11 | 1997 | ADOPT IN-HOUSE MATERIAL GENERATION | $10,130 | $10,250 | Implemented |
AS0212 # 12 Y:1997 | 12 | 1997 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $5,201,240 | $28,946 | Not Implemented |
MA0401 # 01 Y:1997 | 01 | 1997 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $21,102 | $70,000 | Not Implemented |
MA0401 # 02 Y:1997 | 02 | 1997 | COVER OPEN TANKS | $10,768 | $0 | Implemented |
MA0401 # 03 Y:1997 | 03 | 1997 | AVOID COOLING OF PROCESS STREAMS OR MATERIALS THAT MUST SUBSEQUENTLY BE HEATED | $1,927 | $0 | Implemented |
MA0401 # 04 Y:1997 | 04 | 1997 | UPGRADE CONTROLS ON COMPRESSORS | $4,875 | $10,000 | Implemented |
MA0401 # 05 Y:1997 | 05 | 1997 | AVOID COOLING OF PROCESS STREAMS OR MATERIALS THAT MUST SUBSEQUENTLY BE HEATED | $4,934 | $15,000 | Not Implemented |
MA0401 # 06 Y:1997 | 06 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $826 | $5,321 | Implemented |
MA0401 # 07 Y:1997 | 07 | 1997 | RECYCLE CASTING SAND | $10,174 | $30,000 | Not Implemented |
MA0401 # 08 Y:1997 | 08 | 1997 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $8,331 | $17,307 | Not Implemented |
MA0401 # 09 Y:1997 | 09 | 1997 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $50,655 | $5,000 | Not Implemented |
MA0401 # 10 Y:1997 | 10 | 1997 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $2,700 | $400 | Not Implemented |
MA0401 # 11 Y:1997 | 11 | 1997 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $3,660 | $2,000 | Not Implemented |
MO0215 # 01 Y:1997 | 01 | 1997 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $9,696 | $25,000 | Implemented |