Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
10,549
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0269 # 04 Y:1997 | 04 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,446 | $400 | Not Implemented |
ND0269 # 05 Y:1997 | 05 | 1997 | RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS | $909 | $30 | Not Implemented |
ND0269 # 06 Y:1997 | 06 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $791 | $300 | Not Implemented |
ND0269 # 07 Y:1997 | 07 | 1997 | INSTALL OCCUPANCY SENSORS | $718 | $600 | Not Implemented |
ND0269 # 08 Y:1997 | 08 | 1997 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $536 | $250 | Not Implemented |
ND0269 # 09 Y:1997 | 09 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $171 | $495 | Not Implemented |
MS0082 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $356 | $1,798 | Not Implemented |
MS0082 # 02 Y:1997 | 02 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,263 | $7,718 | Not Implemented |
MS0082 # 03 Y:1997 | 03 | 1997 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $43,945 | $22,016 | Not Implemented |
MS0082 # 04 Y:1997 | 04 | 1997 | USE SAND FOR OTHER PURPOSES (EG CONSTRUCTION FILL, COVER FOR MUNICIPAL LANDFILLS) | $46,250 | $0 | Implemented |
MS0082 # 05 Y:1997 | 05 | 1997 | SELL OIL TO RECYCLER | $205 | $0 | Not Implemented |
MS0082 # 06 Y:1997 | 06 | 1997 | MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE | $33,600 | $153,600 | Not Implemented |
UD0515 # 01 Y:1997 | 01 | 1997 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $36,109 | $60,000 | Implemented |
UD0515 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,688 | $11,020 | Not Implemented |
UD0515 # 03 Y:1997 | 03 | 1997 | CONSOLIDATE FREIGHT SHIPMENTS AND/OR DELIVERIES | $34,031 | $25,000 | Not Implemented |
UD0515 # 04 Y:1997 | 04 | 1997 | MOVE PRODUCT USING MECHANICAL MEANS | $67,125 | $2,500 | Not Implemented |
UD0515 # 05 Y:1997 | 05 | 1997 | MOVE PRODUCT USING MECHANICAL MEANS | $19,500 | $8,000 | Not Implemented |
UD0515 # 06 Y:1997 | 06 | 1997 | USE OTHER METHODS FOR NEUTRALIZATION | $5,655 | $500 | Not Implemented |
UD0515 # 07 Y:1997 | 07 | 1997 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $2,789 | $200 | Implemented |
UD0515 # 08 Y:1997 | 08 | 1997 | CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS | $1,875 | $0 | Not Implemented |
UD0515 # 09 Y:1997 | 09 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $40,143 | $150,000 | Implemented |
WI0295 # 01 Y:1997 | 01 | 1997 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $119,785 | $0 | n/a |
WI0295 # 02 Y:1997 | 02 | 1997 | MAINTAIN/ENLARGE A STOCK OF SPARE PARTS | $68,700 | $0 | n/a |
WI0295 # 03 Y:1997 | 03 | 1997 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $14,566 | $0 | n/a |
WI0295 # 04 Y:1997 | 04 | 1997 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $6,488 | $10,000 | n/a |