Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
10,364
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0151 # 06 Y:1996 | 06 | 1996 | INSTALL SPECTRAL REFLECTORS / DELAMP | $4,479 | $5,640 | Implemented |
SD0151 # 07 Y:1996 | 07 | 1996 | INSTALL OCCUPANCY SENSORS | $426 | $369 | Implemented |
SD0151 # 08 Y:1996 | 08 | 1996 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $2,885 | $1,450 | Implemented |
SD0151 # 09 Y:1996 | 09 | 1996 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $91 | $200 | Implemented |
OR0262 # 01 Y:1996 | 01 | 1996 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $35,059 | $1,690 | Not Implemented |
OR0262 # 02 Y:1996 | 02 | 1996 | FILTER AND REUSE HYDRAULIC OIL | $53,160 | $3,850 | Not Implemented |
OR0262 # 03 Y:1996 | 03 | 1996 | REDUCE SCRAP PRODUCTION | $130,236 | $29,640 | Not Implemented |
OR0262 # 04 Y:1996 | 04 | 1996 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $28,400 | $8,250 | Not Implemented |
OR0262 # 05 Y:1996 | 05 | 1996 | OPTIMIZE PLANT POWER FACTOR | $3,101 | $6,600 | Not Implemented |
OR0262 # 06 Y:1996 | 06 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,084 | $10,701 | Not Implemented |
OR0262 # 07 Y:1996 | 07 | 1996 | UPGRADE CONTROLS ON COMPRESSORS | $6,882 | $27,454 | Not Implemented |
IA0143 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,183 | $640 | Implemented |
IA0143 # 02 Y:1996 | 02 | 1996 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,401 | $1,128 | Not Implemented |
IA0143 # 03 Y:1996 | 03 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,672 | $463 | Implemented |
IA0143 # 04 Y:1996 | 04 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $282 | $25 | Implemented |
IA0143 # 05 Y:1996 | 05 | 1996 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $27,825 | $54,500 | Implemented |
IA0143 # 06 Y:1996 | 06 | 1996 | UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS | $5,446 | $16,125 | Not Implemented |
MA0364 # 01 Y:1996 | 01 | 1996 | ADOPT IN-HOUSE MATERIAL GENERATION | $20,546 | $119,500 | Not Implemented |
MA0364 # 02 Y:1996 | 02 | 1996 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $5,996 | $2,009 | Not Implemented |
MA0364 # 03 Y:1996 | 03 | 1996 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $652 | $12,000 | Not Implemented |
MA0364 # 04 Y:1996 | 04 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,606 | $0 | Not Implemented |
MA0364 # 05 Y:1996 | 05 | 1996 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,454 | $900 | Not Implemented |
MA0364 # 06 Y:1996 | 06 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $755 | $4,800 | Not Implemented |
MA0364 # 07 Y:1996 | 07 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $477 | $1,100 | Implemented |
MA0364 # 08 Y:1996 | 08 | 1996 | REDUCE VENTILATION AIR | $360 | $0 | Not Implemented |