IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

224

matching recommendations
Reset
SIC 33 Primary Metal Industries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0140 # 08 Y:1998 08 1998 INSTALL REFRIGERATION SYSTEM TO COOL PRODUCT $47,500 $135,000 Not Implemented
NC0140 # 09 Y:1998 09 1998 ADD ADDITIONAL PRODUCTION SHIFT $237,500 $12,000 Implemented
NC0139 # 01 Y:1998 01 1998 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $14,306 $18,000 Not Implemented
NC0139 # 02 Y:1998 02 1998 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $3,424 $1,800 Implemented
NC0139 # 03 Y:1998 03 1998 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $34,875 $2,500 Not Implemented
NC0139 # 04 Y:1998 04 1998 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $5,815 $25,000 Not Implemented
NC0139 # 05 Y:1998 05 1998 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $42,277 $70,000 Not Implemented
NC0139 # 06 Y:1998 06 1998 USE OTHER WASTE CONCENTRATION METHODS $4,704 $4,000 Not Implemented
NC0139 # 07 Y:1998 07 1998 REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL $418,000 $750,000 Not Implemented
NC0132 # 01 Y:1998 01 1998 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $9,465 $14,500 Not Implemented
NC0132 # 02 Y:1998 02 1998 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $6,949 $11,150 Not Implemented
NC0132 # 03 Y:1998 03 1998 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,486 $2,688 Not Implemented
NC0132 # 04 Y:1998 04 1998 INSULATE BARE EQUIPMENT $2,506 $2,940 Not Implemented
NC0132 # 05 Y:1998 05 1998 INSTALL OCCUPANCY SENSORS $1,455 $1,600 Not Implemented
NC0132 # 06 Y:1998 06 1998 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $440 $1,333 Not Implemented
NC0132 # 07 Y:1998 07 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,816 $13,801 Not Implemented
NC0132 # 08 Y:1998 08 1998 CONTRACT A WOOD PALLET RECYCLING COMPANY $900 $200 Not Implemented
NC0132 # 09 Y:1998 09 1998 OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES $119,000 $500 Not Implemented
NC0082 # 01 Y:1996 01 1996 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $1,228 $2,500 Implemented
NC0082 # 02 Y:1996 02 1996 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $1,084 $3,000 Not Implemented
NC0082 # 03 Y:1996 03 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $534 $330 Not Implemented
NC0082 # 04 Y:1996 04 1996 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $2,118 $100 Implemented
NC0082 # 05 Y:1996 05 1996 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $820 $200 Implemented
NC0082 # 06 Y:1996 06 1996 REDUCE VENTILATION AIR $4,208 $10,000 Not Implemented
NC0082 # 07 Y:1996 07 1996 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $91 $80 Not Implemented