Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

403

matching recommendations
Reset
SIC 33 Primary Metal Industries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WM0110 # 01 Y:2017 01 2017 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $92,862 $250,000 Not Implemented
WM0103 # 11 Y:2017 11 2017 INSULATE BARE EQUIPMENT $1,543 $504 Not Implemented
WM0103 # 10 Y:2017 10 2017 USE OPTIMUM TEMPERATURE $9,226 $0 Not Implemented
WM0103 # 09 Y:2017 09 2017 TURN OFF EQUIPMENT WHEN NOT IN USE $131 $0 Not Implemented
WM0103 # 08 Y:2017 08 2017 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $8,484 $3,000 Not Implemented
WM0103 # 07 Y:2017 07 2017 USE SYNTHETIC LUBRICANT $26,785 $47,960 Not Implemented
WM0103 # 06 Y:2017 06 2017 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $459 $690 Not Implemented
WM0103 # 05 Y:2017 05 2017 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $7,422 $0 Not Implemented
WM0103 # 04 Y:2017 04 2017 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,488 $302 Not Implemented
WM0103 # 03 Y:2017 03 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $19,337 $24,875 Not Implemented
WM0103 # 02 Y:2017 02 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $823 $800 Not Implemented
WM0103 # 01 Y:2017 01 2017 INSTALL OCCUPANCY SENSORS $2,287 $1,245 Not Implemented
WM0086 # 07 Y:2016 07 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $220 $321 Not Implemented
WM0086 # 06 Y:2016 06 2016 INSTALL OCCUPANCY SENSORS $481 $320 Not Implemented
WM0086 # 05 Y:2016 05 2016 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $258 $200 Not Implemented
WM0086 # 04 Y:2016 04 2016 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $548 $318 Not Implemented
WM0086 # 03 Y:2016 03 2016 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $533 $276 Not Implemented
WM0086 # 02 Y:2016 02 2016 PREHEAT COMBUSTION AIR WITH WASTE HEAT $1,302 $4,004 Not Implemented
WM0086 # 01 Y:2016 01 2016 USE BATCH FIRING WITH KILN "FURNITURE" SPECIFICALLY DESIGNED $3,034 $400 Not Implemented
WM0081 # 09 Y:2016 09 2016 INSTALL OCCUPANCY SENSORS $450 $180 Not Implemented
WM0081 # 08 Y:2016 08 2016 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,981 $2,000 Implemented
WM0081 # 07 Y:2016 07 2016 INSULATE BARE EQUIPMENT $4,636 $7,160 Not Implemented
WM0081 # 06 Y:2016 06 2016 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $6,837 $2,625 Not Implemented
WM0081 # 05 Y:2016 05 2016 TURN OFF EQUIPMENT WHEN NOT IN USE $8,381 $1,000 Implemented
WM0081 # 04 Y:2016 04 2016 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $8,666 $4,583 Not Implemented