IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

10,353

matching recommendations
Reset
SIC 33 Primary Metal Industries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SU0377 # 07 Y:2015 07 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,638 $5,256 Implemented
IP0031 # 01 Y:2014 01 2014 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $5,065,497 $375,000 Not Implemented
IP0031 # 02 Y:2014 02 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $22,715 $14,486 Implemented
IP0031 # 03 Y:2014 03 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,679 $59,914 Implemented
IP0031 # 04 Y:2014 04 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,588 $22,450 Implemented
IP0031 # 05 Y:2014 05 2014 RECOVER WASTE HEAT FROM EQUIPMENT $1,661,000 $17,500,000 Not Implemented
UD0916 # 01 Y:2014 01 2014 TURN OFF EQUIPMENT WHEN NOT IN USE $5,270 $0 Not Implemented
UD0916 # 02 Y:2014 02 2014 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,027 $0 Not Implemented
UD0916 # 03 Y:2014 03 2014 INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS $6,076 $11,700 Not Implemented
UD0916 # 04 Y:2014 04 2014 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $25,351 $43,280 Not Implemented
UD0916 # 05 Y:2014 05 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,413 $26,040 Not Implemented
UD0916 # 06 Y:2014 06 2014 INSTALL OCCUPANCY SENSORS $503 $500 Implemented
UD0916 # 07 Y:2014 07 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,426 $4,150 Not Implemented
UD0916 # 08 Y:2014 08 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $896 $0 Not Implemented
UD0916 # 09 Y:2014 09 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,978 $1,000 Implemented
UD0916 # 10 Y:2014 10 2014 UPGRADE CONTROLS ON COMPRESSORS $10,562 $110,000 Implemented
UD0916 # 11 Y:2014 11 2014 ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF $9,661 $40,000 Not Implemented
UD0916 # 12 Y:2014 12 2014 CONTRACT A WOOD PALLET RECYCLING COMPANY $12,800 $0 Implemented
TT0142 # 01 Y:2014 01 2014 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,305 $1,400 Implemented
TT0142 # 02 Y:2014 02 2014 INSTALL / REPAIR INSULATION ON STEAM LINES $299 $596 Not Implemented
TT0142 # 03 Y:2014 03 2014 INSTALL / REPAIR INSULATION ON STEAM LINES $861 $1,662 Not Implemented
TT0142 # 04 Y:2014 04 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,651 $3,000 Implemented
TT0142 # 05 Y:2014 05 2014 DISCONNECT BALLASTS $555 $60 Not Implemented
TT0142 # 06 Y:2014 06 2014 USE PHOTOCELL CONTROLS $49 $45 Implemented
WV0496 # 01 Y:2014 01 2014 USE DEMAND CONTROLLER OR LOAD SHEDDER $46,701 $10,800 Not Implemented