Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
345
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0589 # 05 Y:2000 | 05 | 2000 | RECOVER AND REUSE WASTE MATERIAL | $20,274 | $59,400 | Implemented |
OK0533 # 01 Y:1997 | 01 | 1997 | MOVE PRODUCT USING MECHANICAL MEANS | $22,960 | $110,000 | Not Implemented |
OK0533 # 02 Y:1997 | 02 | 1997 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $14,444 | $17,000 | Implemented |
OK0533 # 03 Y:1997 | 03 | 1997 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $11,845 | $8,350 | Not Implemented |
OK0533 # 04 Y:1997 | 04 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,426 | $0 | Implemented |
OK0533 # 05 Y:1997 | 05 | 1997 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $750 | $0 | Implemented |
OK0533 # 06 Y:1997 | 06 | 1997 | INSTALL OCCUPANCY SENSORS | $390 | $660 | Not Implemented |
OK0525 # 01 Y:1997 | 01 | 1997 | RECYCLE CASTING SAND | $290,422 | $282,500 | Not Implemented |
OK0525 # 02 Y:1997 | 02 | 1997 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $9,080 | $1,260 | Not Implemented |
OK0525 # 03 Y:1997 | 03 | 1997 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $5,369 | $6,768 | Implemented |
OK0525 # 04 Y:1997 | 04 | 1997 | INSTALL SET-BACK TIMERS | $3,150 | $630 | Implemented |
OK0525 # 05 Y:1997 | 05 | 1997 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $2,850 | $4,477 | Not Implemented |
OK0525 # 06 Y:1997 | 06 | 1997 | IMPROVE COMBUSTION CONTROL CAPABILITY | $1,033 | $2,805 | Not Implemented |
OK0525 # 07 Y:1997 | 07 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $147 | $278 | Not Implemented |
OK0525 # 08 Y:1997 | 08 | 1997 | INSTALL OCCUPANCY SENSORS | $134 | $116 | Implemented |
OK0525 # 09 Y:1997 | 09 | 1997 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $28,080 | $2,090 | Not Implemented |
OK0517 # 01 Y:1997 | 01 | 1997 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $124,800 | $150,000 | Implemented |
OK0517 # 02 Y:1997 | 02 | 1997 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $15,653 | $36,725 | Implemented |
OK0517 # 03 Y:1997 | 03 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,810 | $5,000 | Not Implemented |
OK0517 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $434 | $1,872 | Implemented |
OK0517 # 05 Y:1997 | 05 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $45 | $40 | Implemented |
OK0430 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,200 | $5,400 | Implemented |
OK0430 # 02 Y:1994 | 02 | 1994 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,505 | $900 | Implemented |
OK0430 # 03 Y:1994 | 03 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,262 | $1,173 | Implemented |
OK0430 # 04 Y:1994 | 04 | 1994 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $909 | $0 | Implemented |