IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,064

matching recommendations
Reset
SIC 331 Blast Furnace And Basic Steel Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0502 # 03 Y:2017 03 2017 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $7,986 $0 Not Implemented
UF0502 # 04 Y:2017 04 2017 IMPROVE COMBUSTION CONTROL CAPABILITY $2,634 $0 Not Implemented
UF0502 # 05 Y:2017 05 2017 REDESIGN PROCESS $1,490 $1,800 Not Implemented
UF0502 # 06 Y:2017 06 2017 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,047 $57 Not Implemented
OK0950 # 01 Y:2016 01 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $23,777 $12,727 Not Implemented
OK0950 # 02 Y:2016 02 2016 TURN OFF EQUIPMENT WHEN NOT IN USE $22,408 $2,125 Not Implemented
OK0950 # 03 Y:2016 03 2016 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $20,070 $1,790 Not Implemented
OK0950 # 04 Y:2016 04 2016 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,968 $666 Not Implemented
OK0950 # 05 Y:2016 05 2016 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $9,245 $100 Not Implemented
OK0950 # 06 Y:2016 06 2016 OPTIMIZE PLANT POWER FACTOR $3,100 $13,740 Not Implemented
TT0180 # 01 Y:2016 01 2016 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $27,451 $700 Implemented
TT0180 # 02 Y:2016 02 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $27,289 $0 Implemented
TT0180 # 03 Y:2016 03 2016 UPGRADE CONTROLS ON COMPRESSORS $25,771 $40,000 Implemented
TT0180 # 04 Y:2016 04 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $22,587 $100,037 Implemented
TT0180 # 05 Y:2016 05 2016 INSTALL COMMON HEADER ON COMPRESSORS $8,381 $11,700 Implemented
TT0180 # 06 Y:2016 06 2016 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $2,293 $10,800 Not Implemented
TT0180 # 07 Y:2016 07 2016 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,241 $2,500 Implemented
TT0180 # 08 Y:2016 08 2016 INSTALL TIMERS AND/OR THERMOSTATS $2,047 $1,575 Implemented
TT0180 # 09 Y:2016 09 2016 DEVELOP A REPAIR/REPLACE POLICY $408 $661 Not Implemented
SD0536 # 01 Y:2016 01 2016 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $91,093 $350,298 Not Implemented
SD0536 # 02 Y:2016 02 2016 MODIFY PROCESS TO REDUCE MATERIAL USE/COST $23,163 $68,259 Not Implemented
SD0536 # 03 Y:2016 03 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,468 $8,787 Not Implemented
SD0536 # 04 Y:2016 04 2016 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $6,259 $11,760 Not Implemented
SD0536 # 05 Y:2016 05 2016 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $5,594 $11,180 Not Implemented
SD0536 # 06 Y:2016 06 2016 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,995 $648 Implemented