Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,097

matching recommendations
Reset
SIC 331 Blast Furnace And Basic Steel Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UK1801 # 02 Y:2018 02 2018 INSTALL OCCUPANCY SENSORS $2,773 $1,959 Implemented
UK1801 # 03 Y:2018 03 2018 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $26,076 $3,990 Not Implemented
UK1801 # 04 Y:2018 04 2018 DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING $23,118 $11,500 Not Implemented
UK1801 # 05 Y:2018 05 2018 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $13,263 $2,190 Implemented
UK1801 # 06 Y:2018 06 2018 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $860 $1,250 Implemented
UK1801 # 07 Y:2018 07 2018 INSULATE BARE EQUIPMENT $8,475 $2,977 Not Implemented
UK1801 # 08 Y:2018 08 2018 INSULATE BARE EQUIPMENT $3,719 $1,526 Not Implemented
UK1801 # 09 Y:2018 09 2018 PREHEAT COMBUSTION AIR WITH WASTE HEAT $3,865 $5,895 Not Implemented
UK1801 # 10 Y:2018 10 2018 PREHEAT COMBUSTION AIR WITH WASTE HEAT $3,756 $5,475 Not Implemented
UK1801 # 11 Y:2018 11 2018 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,054 $0 Not Implemented
IC0194 # 01 Y:2017 01 2017 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $124,626 $220,275 Implemented
IC0194 # 02 Y:2017 02 2017 OPTIMIZE PLANT POWER FACTOR $87,344 $137,763 Implemented
IC0194 # 03 Y:2017 03 2017 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $20,467 $8,000 Not Implemented
IC0194 # 04 Y:2017 04 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,741 $8,162 Not Implemented
OK0968 # 01 Y:2017 01 2017 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $17,259 $3,000 Implemented
OK0968 # 02 Y:2017 02 2017 TURN OFF EQUIPMENT WHEN NOT IN USE $5,490 $0 Implemented
OK0968 # 03 Y:2017 03 2017 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,554 $1,388 Implemented
OK0968 # 04 Y:2017 04 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $55,717 $159,110 Implemented
OK0968 # 05 Y:2017 05 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,670 $90,081 Implemented
OK0968 # 06 Y:2017 06 2017 USE SHAFT TYPE FURNACES FOR PREHEATING INCOMING MATERIAL $670,334 $2,422,500 Not Implemented
OK0968 # 07 Y:2017 07 2017 AVOID COOLING OF PROCESS STREAMS OR MATERIALS THAT MUST SUBSEQUENTLY BE HEATED $157,581 $3,000 Not Implemented
OK0961 # 01 Y:2017 01 2017 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $1,024 $5,000 Not Implemented
OK0961 # 02 Y:2017 02 2017 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $1,730 $400 Implemented
OK0961 # 03 Y:2017 03 2017 INSTALL SET-BACK TIMERS $605 $800 Not Implemented
OK0961 # 04 Y:2017 04 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $80,050 $185,484 Not Implemented