Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,097
matching recommendationsSIC | 331 | Blast Furnace And Basic Steel Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UK1801 # 02 Y:2018 | 02 | 2018 | INSTALL OCCUPANCY SENSORS | $2,773 | $1,959 | Implemented |
UK1801 # 03 Y:2018 | 03 | 2018 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $26,076 | $3,990 | Not Implemented |
UK1801 # 04 Y:2018 | 04 | 2018 | DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING | $23,118 | $11,500 | Not Implemented |
UK1801 # 05 Y:2018 | 05 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,263 | $2,190 | Implemented |
UK1801 # 06 Y:2018 | 06 | 2018 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $860 | $1,250 | Implemented |
UK1801 # 07 Y:2018 | 07 | 2018 | INSULATE BARE EQUIPMENT | $8,475 | $2,977 | Not Implemented |
UK1801 # 08 Y:2018 | 08 | 2018 | INSULATE BARE EQUIPMENT | $3,719 | $1,526 | Not Implemented |
UK1801 # 09 Y:2018 | 09 | 2018 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $3,865 | $5,895 | Not Implemented |
UK1801 # 10 Y:2018 | 10 | 2018 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $3,756 | $5,475 | Not Implemented |
UK1801 # 11 Y:2018 | 11 | 2018 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,054 | $0 | Not Implemented |
IC0194 # 01 Y:2017 | 01 | 2017 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $124,626 | $220,275 | Implemented |
IC0194 # 02 Y:2017 | 02 | 2017 | OPTIMIZE PLANT POWER FACTOR | $87,344 | $137,763 | Implemented |
IC0194 # 03 Y:2017 | 03 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $20,467 | $8,000 | Not Implemented |
IC0194 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,741 | $8,162 | Not Implemented |
OK0968 # 01 Y:2017 | 01 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,259 | $3,000 | Implemented |
OK0968 # 02 Y:2017 | 02 | 2017 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,490 | $0 | Implemented |
OK0968 # 03 Y:2017 | 03 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,554 | $1,388 | Implemented |
OK0968 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $55,717 | $159,110 | Implemented |
OK0968 # 05 Y:2017 | 05 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,670 | $90,081 | Implemented |
OK0968 # 06 Y:2017 | 06 | 2017 | USE SHAFT TYPE FURNACES FOR PREHEATING INCOMING MATERIAL | $670,334 | $2,422,500 | Not Implemented |
OK0968 # 07 Y:2017 | 07 | 2017 | AVOID COOLING OF PROCESS STREAMS OR MATERIALS THAT MUST SUBSEQUENTLY BE HEATED | $157,581 | $3,000 | Not Implemented |
OK0961 # 01 Y:2017 | 01 | 2017 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,024 | $5,000 | Not Implemented |
OK0961 # 02 Y:2017 | 02 | 2017 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $1,730 | $400 | Implemented |
OK0961 # 03 Y:2017 | 03 | 2017 | INSTALL SET-BACK TIMERS | $605 | $800 | Not Implemented |
OK0961 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $80,050 | $185,484 | Not Implemented |