Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
262
matching recommendationsSIC | 331 | Blast Furnace And Basic Steel Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0302 # 06 Y:1997 | 06 | 1997 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $6,051 | $7,000 | Not Implemented |
WI0302 # 07 Y:1997 | 07 | 1997 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,805 | $0 | Implemented |
WI0302 # 08 Y:1997 | 08 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,649 | $5,500 | Not Implemented |
WI0302 # 09 Y:1997 | 09 | 1997 | INSTALL OCCUPANCY SENSORS | $281 | $600 | Not Implemented |
BD0087 # 01 Y:1997 | 01 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $20,443 | $40,890 | Implemented |
BD0087 # 02 Y:1997 | 02 | 1997 | LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE | $7,026 | $8,500 | Not Implemented |
BD0087 # 03 Y:1997 | 03 | 1997 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $5,680 | $5,100 | Implemented |
BD0087 # 04 Y:1997 | 04 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $5,171 | $3,750 | Not Implemented |
BD0087 # 05 Y:1997 | 05 | 1997 | INSTALL OCCUPANCY SENSORS | $1,365 | $1,125 | Implemented |
BD0087 # 06 Y:1997 | 06 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $10,295 | $7,000 | Implemented |
BD0087 # 07 Y:1997 | 07 | 1997 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $14,951 | $3,000 | Implemented |
WI0281 # 01 Y:1996 | 01 | 1996 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $33,184 | $80,000 | Not Implemented |
WI0281 # 02 Y:1996 | 02 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $30,144 | $12,950 | Not Implemented |
WI0281 # 03 Y:1996 | 03 | 1996 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $19,250 | $0 | Not Implemented |
WI0281 # 04 Y:1996 | 04 | 1996 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $19,457 | $15,000 | Not Implemented |
WI0281 # 05 Y:1996 | 05 | 1996 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $11,051 | $26,220 | Not Implemented |
WI0281 # 06 Y:1996 | 06 | 1996 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $8,879 | $0 | Implemented |
WI0281 # 07 Y:1996 | 07 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,899 | $210 | Implemented |
WI0281 # 08 Y:1996 | 08 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $870 | $740 | Not Implemented |
WI0281 # 09 Y:1996 | 09 | 1996 | INSTALL AUTOMATIC STACK DAMPER | $931 | $1,100 | Not Implemented |
WI0281 # 10 Y:1996 | 10 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,554 | $701 | Implemented |
BD0037 # 01 Y:1995 | 01 | 1995 | INSULATE BARE EQUIPMENT | $602 | $174 | Not Implemented |
BD0037 # 02 Y:1995 | 02 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $706 | $359 | Implemented |
BD0037 # 03 Y:1995 | 03 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,988 | $3,590 | Implemented |
BD0037 # 04 Y:1995 | 04 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,911 | $5,060 | Implemented |