Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
280
matching recommendationsSIC | 3315 | Steel Wire And Related Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0084 # 04 Y:2004 | 04 | 2004 | REPAIR AND ELIMINATE STEAM LEAKS | $4,809 | $585 | Implemented |
IC0084 # 06 Y:2004 | 06 | 2004 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $943 | $582,998 | Implemented |
IC0084 # 08 Y:2004 | 08 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM | $48,922 | $200 | Implemented |
IC0084 # 09 Y:2004 | 09 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $124,469 | $513 | Implemented |
IC0084 # 10 Y:2004 | 10 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $794 | $5,100 | Implemented |
IC0084 # 11 Y:2004 | 11 | 2004 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $122 | $0 | Implemented |
IC0084 # 13 Y:2004 | 13 | 2004 | SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING | $197 | $240 | Implemented |
UF0342 # 06 Y:2004 | 06 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,148 | $0 | Implemented |
BD0253 # 08 Y:2004 | 08 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,816 | $2,400 | Implemented |
BD0253 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,360 | $1,275 | Implemented |
BD0253 # 03 Y:2004 | 03 | 2004 | INSTALL AUTOMATIC STACK DAMPER | $2,979 | $5,500 | Implemented |
BD0253 # 01 Y:2004 | 01 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,484 | $13,260 | Implemented |
BD0253 # 16 Y:2004 | 16 | 2004 | $8,820 | $144 | Implemented | |
BD0253 # 15 Y:2004 | 15 | 2004 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $754 | $500 | Implemented |
BD0253 # 10 Y:2004 | 10 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,561 | $385 | Implemented |
MS0239 # 03 Y:2003 | 03 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $10,196 | $17,859 | Implemented |
MS0239 # 07 Y:2003 | 07 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,839 | $1,000 | Implemented |
MS0239 # 05 Y:2003 | 05 | 2003 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $2,265 | $6,000 | Implemented |
MS0239 # 04 Y:2003 | 04 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $9,584 | $15,350 | Implemented |
BD0240 # 06 Y:2003 | 06 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,033 | $7,500 | Implemented |
BD0240 # 02 Y:2003 | 02 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $16,799 | $33,005 | Implemented |
BD0240 # 11 Y:2003 | 11 | 2003 | USE PHOTOCELL CONTROLS | $3,929 | $1,250 | Implemented |
BD0240 # 15 Y:2003 | 15 | 2003 | MINIMIZE WATER USAGE | $14,330 | $400 | Implemented |
OK0673 # 04 Y:2003 | 04 | 2003 | USE COMPRESSOR AIR FILTERS | $7,440 | $670 | Implemented |
OK0673 # 01 Y:2003 | 01 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,017 | $1,000 | Implemented |