Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
661
matching recommendationsSIC | 3315 | Steel Wire And Related Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AR0163 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,841 | $1,621 | Not Implemented |
AR0163 # 02 Y:1999 | 02 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,383 | $120 | Not Implemented |
AR0163 # 03 Y:1999 | 03 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $226 | $2,400 | Not Implemented |
AR0163 # 04 Y:1999 | 04 | 1999 | USE OPTIMUM THICKNESS INSULATION | $11,267 | $1,408 | Not Implemented |
AR0163 # 05 Y:1999 | 05 | 1999 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $251,669 | $66,400 | Not Implemented |
AR0163 # 06 Y:1999 | 06 | 1999 | USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES | $3,065 | $225 | Not Implemented |
AR0146 # 01 Y:1998 | 01 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $6,771 | $840 | Implemented |
AR0146 # 02 Y:1998 | 02 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $16,850 | $300 | Implemented |
AR0146 # 03 Y:1998 | 03 | 1998 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $29,234 | $18,900 | Implemented |
AR0146 # 04 Y:1998 | 04 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,398 | $1,340 | Implemented |
AR0146 # 05 Y:1998 | 05 | 1998 | REDUCE OR ELIMINATE WASTE | $224,855 | $8,100 | Implemented |
AR0146 # 06 Y:1998 | 06 | 1998 | REPROCESS SPENT OILS ON SITE FOR RE-USE | $17,264 | $0 | Not Implemented |
AR0146 # 07 Y:1998 | 07 | 1998 | PURCHASE RE-CONDITIONED MATERIAL INSTEAD OF NEW | $3,780 | $0 | Implemented |
AR0146 # 08 Y:1998 | 08 | 1998 | INSTALL AUTOMATIC PACKING EQUIPMENT | $98,162 | $386,400 | Implemented |
UD0554 # 01 Y:1998 | 01 | 1998 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $101,400 | $60,000 | Not Implemented |
UD0554 # 02 Y:1998 | 02 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $47,736 | $2,000 | Not Implemented |
UD0554 # 03 Y:1998 | 03 | 1998 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $28,560 | $8,000 | Implemented |
UD0554 # 04 Y:1998 | 04 | 1998 | INSULATE BARE EQUIPMENT | $19,707 | $21,120 | Not Implemented |
UD0554 # 05 Y:1998 | 05 | 1998 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,026 | $1,850 | Implemented |
UD0554 # 06 Y:1998 | 06 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,699 | $6,419 | Not Implemented |
UD0554 # 07 Y:1998 | 07 | 1998 | COVER OPEN TANKS | $2,023 | $1,050 | Implemented |
NC0140 # 01 Y:1998 | 01 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $489 | $852 | Implemented |
NC0140 # 02 Y:1998 | 02 | 1998 | INSULATE BARE EQUIPMENT | $4,227 | $1,090 | Implemented |
NC0140 # 03 Y:1998 | 03 | 1998 | COVER OPEN TANKS | $5,237 | $10,500 | Not Implemented |
NC0140 # 04 Y:1998 | 04 | 1998 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $7,006 | $6,000 | Not Implemented |