Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,069

matching recommendations
Reset
SIC 332 Iron And Steel Foundries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0824 # 14 Y:2010 14 2010 INSULATE BARE EQUIPMENT $61,285 $5,152 Not Implemented
UD0824 # 15 Y:2010 15 2010 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT $43,001 $1,243,001 Not Implemented
UD0824 # 16 Y:2010 16 2010 INSTALL AUTOMATIC STACK DAMPER $22,399 $500 Not Implemented
UD0824 # 17 Y:2010 17 2010 COVER OPEN TANKS $8,613 $17,226 Not Implemented
UD0824 # 18 Y:2010 18 2010 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE $18,106 $36,212 Not Implemented
UD0824 # 19 Y:2010 19 2010 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $6,081 $11,700 Not Implemented
UD0824 # 20 Y:2010 20 2010 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,372 $11,000 Not Implemented
UA0044 # 01 Y:2010 01 2010 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,400 $0 Implemented
UA0044 # 02 Y:2010 02 2010 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $2,187 $0 Implemented
UA0044 # 03 Y:2010 03 2010 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $31,813 $50,000 Implemented
UA0044 # 04 Y:2010 04 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $29,108 $0 Not Implemented
UA0044 # 05 Y:2010 05 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,303 $11,000 Implemented
UA0044 # 06 Y:2010 06 2010 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,858 $2,000 Implemented
UA0044 # 07 Y:2010 07 2010 TURN OFF EQUIPMENT WHEN NOT IN USE $25,366 $0 Implemented
UA0044 # 08 Y:2010 08 2010 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $166 $320 Not Implemented
UA0044 # 09 Y:2010 09 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,163 $0 Not Implemented
UA0044 # 10 Y:2010 10 2010 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $91,712 $375,000 Not Implemented
UA0044 # 11 Y:2010 11 2010 INSTALL / REPAIR INSULATION ON STEAM LINES $786 $494 Not Implemented
MZ0046 # 01 Y:2009 01 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $54,631 $54,630 Implemented
MZ0046 # 02 Y:2009 02 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,025 $14,100 Implemented
MZ0046 # 03 Y:2009 03 2009 INSTALL OCCUPANCY SENSORS $18,406 $1,380 Implemented
MZ0046 # 04 Y:2009 04 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $53,749 $1,300 Implemented
MZ0046 # 05 Y:2009 05 2009 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $10,771 $0 Implemented
MZ0046 # 06 Y:2009 06 2009 INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS $8,620 $1,800 Implemented
MZ0046 # 07 Y:2009 07 2009 RECOVER WASTE HEAT FROM EQUIPMENT $205,683 $30,000 Not Implemented