Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,069
matching recommendationsSIC | 332 | Iron And Steel Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0046 # 08 Y:2009 | 08 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,483 | $0 | Implemented |
MZ0046 # 09 Y:2009 | 09 | 2009 | UPGRADE CONTROLS ON COMPRESSORS | $10,100 | $8,000 | Implemented |
IC0163 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $528 | $332 | Implemented |
IC0163 # 02 Y:2009 | 02 | 2009 | INSTALL OCCUPANCY SENSORS | $635 | $538 | Implemented |
IC0163 # 03 Y:2009 | 03 | 2009 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $3,314 | $102 | Implemented |
IC0163 # 04 Y:2009 | 04 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $357 | $0 | Not Implemented |
IC0163 # 05 Y:2009 | 05 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,247 | $0 | Not Implemented |
IC0163 # 06 Y:2009 | 06 | 2009 | USE RADIANT HEATER FOR SPOT HEATING | $9,226 | $39,560 | Not Implemented |
IC0163 # 07 Y:2009 | 07 | 2009 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $6,925 | $17,000 | Implemented |
IC0163 # 08 Y:2009 | 08 | 2009 | RECYCLE WHITE WATER | $2,034 | $771 | Implemented |
IC0163 # 09 Y:2009 | 09 | 2009 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $260 | $0 | Not Implemented |
IC0163 # 10 Y:2009 | 10 | 2009 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $1,689,703 | $0 | Implemented |
UA0040 # 01 Y:2009 | 01 | 2009 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,523 | $37,395 | Not Implemented |
UA0040 # 02 Y:2009 | 02 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $23,360 | $35,000 | Not Implemented |
UA0040 # 03 Y:2009 | 03 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,762 | $1,500 | Implemented |
UA0040 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $28,228 | $171,697 | Implemented |
UA0040 # 05 Y:2009 | 05 | 2009 | INSTALL OCCUPANCY SENSORS | $798 | $272 | Not Implemented |
UA0040 # 06 Y:2009 | 06 | 2009 | INSULATE BARE EQUIPMENT | $3,051 | $55 | Not Implemented |
UA0040 # 07 Y:2009 | 07 | 2009 | INSTALL TIMERS AND/OR THERMOSTATS | $2,586 | $1,870 | Not Implemented |
UA0040 # 08 Y:2009 | 08 | 2009 | UPGRADE CONTROLS ON COMPRESSORS | $52,923 | $20,000 | Not Implemented |
UA0040 # 09 Y:2009 | 09 | 2009 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $224 | $1,445 | Not Implemented |
UA0034 # 01 Y:2009 | 01 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,570 | $0 | Implemented |
UA0034 # 02 Y:2009 | 02 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,970 | $1,500 | Implemented |
UA0034 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,614 | $14,475 | Not Implemented |
UA0034 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,360 | $27,038 | Not Implemented |