Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
49
matching recommendationsSIC | 3321 | Gray And Ductile Iron Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0048 # 09 Y:2002 | 09 | 2002 | AUTOMATE PAYROLL SYSTEM | $364,437 | $18,654 | Not Implemented |
IC0048 # 08 Y:2002 | 08 | 2002 | REDUCE OR ELIMINATE WASTE | $249,587 | $207,024 | Not Implemented |
IC0048 # 07 Y:2002 | 07 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $17,986 | $0 | Implemented |
IC0048 # 06 Y:2002 | 06 | 2002 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $472,157 | $1,500,000 | Not Implemented |
IC0048 # 05 Y:2002 | 05 | 2002 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $40,640 | $108,000 | Not Implemented |
IC0048 # 04 Y:2002 | 04 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $71,006 | $3,130 | Not Implemented |
IC0048 # 03 Y:2002 | 03 | 2002 | TURN OFF EQUIPMENT WHEN NOT IN USE | $56,765 | $35,050 | Implemented |
IC0048 # 02 Y:2002 | 02 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $30,279 | $10,600 | Implemented |
IC0048 # 01 Y:2002 | 01 | 2002 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,063 | $0 | Implemented |
IC0047 # 01 Y:2002 | 01 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $958 | $6,822 | Implemented |
IC0047 # 02 Y:2002 | 02 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $668 | $3,685 | Not Implemented |
IC0047 # 03 Y:2002 | 03 | 2002 | INSTALL OCCUPANCY SENSORS | $1,404 | $1,215 | Implemented |
IC0047 # 04 Y:2002 | 04 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $358 | $900 | Implemented |
IC0047 # 05 Y:2002 | 05 | 2002 | TURN OFF EQUIPMENT WHEN NOT IN USE | $467 | $0 | Not Implemented |
IC0047 # 06 Y:2002 | 06 | 2002 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $960 | $160 | Implemented |
IA0290 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,977 | $829 | Implemented |
IA0290 # 07 Y:2002 | 07 | 2002 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $68,750 | $58,676 | Not Implemented |
IA0290 # 06 Y:2002 | 06 | 2002 | TURN OFF EQUIPMENT WHEN NOT IN USE | $29,170 | $18,259 | Implemented |
IA0290 # 05 Y:2002 | 05 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $18,198 | $2,970 | Not Implemented |
IA0290 # 04 Y:2002 | 04 | 2002 | INSTALL OCCUPANCY SENSORS | $1,312 | $2,128 | Not Implemented |
IA0290 # 03 Y:2002 | 03 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,829 | $13,425 | Implemented |
IA0290 # 02 Y:2002 | 02 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $190 | $25 | Not Implemented |
IC0032 # 09 Y:2002 | 09 | 2002 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $90,684 | $65,000 | Not Implemented |
IC0032 # 08 Y:2002 | 08 | 2002 | INSTALL AUTOMATIC PACKING EQUIPMENT | $25,360 | $8,080 | Not Implemented |
IC0032 # 06 Y:2002 | 06 | 2002 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $25,500 | $132,960 | Not Implemented |