Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
25
matching recommendationsSIC | 335 | Nonferrous Rolling And Drawing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0105 # 02 Y:1993 | 02 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $75 | $147 | Implemented |
AS0105 # 03 Y:1993 | 03 | 1993 | INSTALL OCCUPANCY SENSORS | $546 | $900 | Implemented |
AS0105 # 04 Y:1993 | 04 | 1993 | USE SYNTHETIC LUBRICANT | $623 | $1,230 | Implemented |
AS0105 # 05 Y:1993 | 05 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,244 | $350 | Implemented |
AS0105 # 06 Y:1993 | 06 | 1993 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $1,746 | $0 | Implemented |
AS0105 # 09 Y:1993 | 09 | 1993 | INSULATE BARE EQUIPMENT | $1,707 | $820 | Implemented |
AS0105 # 10 Y:1993 | 10 | 1993 | COVER OPEN TANKS | $5,556 | $0 | Implemented |
AM0189 # 03 Y:1993 | 03 | 1993 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,540 | $70 | Implemented |
AM0189 # 04 Y:1993 | 04 | 1993 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,760 | $0 | Implemented |
AM0189 # 05 Y:1993 | 05 | 1993 | PAY UTILITY BILLS ON TIME | $540 | $0 | Implemented |
AM0189 # 01 Y:1993 | 01 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,300 | $1,500 | Implemented |
KU0402 # 03 Y:1993 | 03 | 1993 | INSTALL SET-BACK TIMERS | $3,940 | $1,000 | Implemented |
KU0402 # 02 Y:1993 | 02 | 1993 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,617 | $3,517 | Implemented |
MO0091 # 05 Y:1993 | 05 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $13,690 | $30,575 | Implemented |
MO0091 # 01 Y:1993 | 01 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,616 | $995 | Implemented |
TN0492 # 03 Y:1993 | 03 | 1993 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,066 | $0 | Implemented |
TN0492 # 07 Y:1993 | 07 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $193 | $0 | Implemented |
TN0492 # 04 Y:1993 | 04 | 1993 | INSTALL TIMERS AND/OR THERMOSTATS | $1,474 | $720 | Implemented |
TN0492 # 02 Y:1993 | 02 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,218 | $840 | Implemented |
AM0177 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $190 | $570 | Implemented |
AM0177 # 05 Y:1993 | 05 | 1993 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $790 | $1,000 | Implemented |
AM0177 # 06 Y:1993 | 06 | 1993 | TURN OFF EQUIPMENT WHEN NOT IN USE | $130 | $0 | Implemented |
AM0177 # 02 Y:1993 | 02 | 1993 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $730 | $6,150 | Implemented |
OK0393 # 02 Y:1993 | 02 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,765 | $5,359 | Implemented |
OK0393 # 03 Y:1993 | 03 | 1993 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $1,582 | $9,804 | Implemented |