Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,036
matching recommendationsSIC | 335 | Nonferrous Rolling And Drawing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0256 # 01 Y:2000 | 01 | 2000 | INSTALL SKYLIGHTS | $18,038 | $27,000 | Implemented |
SD0256 # 02 Y:2000 | 02 | 2000 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,703 | $7,230 | Implemented |
SD0256 # 03 Y:2000 | 03 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $205,696 | $64,500 | Not Implemented |
SD0256 # 04 Y:2000 | 04 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,732 | $5,400 | Not Implemented |
SD0256 # 05 Y:2000 | 05 | 2000 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $290,738 | $0 | Implemented |
UM0163 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $28,712 | $84,426 | Not Implemented |
UM0163 # 02 Y:2000 | 02 | 2000 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,248 | $0 | Implemented |
UM0163 # 03 Y:2000 | 03 | 2000 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,496 | $500 | Implemented |
UM0163 # 04 Y:2000 | 04 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,147 | $300 | Implemented |
UM0163 # 05 Y:2000 | 05 | 2000 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,922 | $1,500 | Not Implemented |
UM0163 # 06 Y:2000 | 06 | 2000 | INSULATE BARE EQUIPMENT | $2,100 | $200 | Not Implemented |
UM0163 # 07 Y:2000 | 07 | 2000 | INSULATE BARE EQUIPMENT | $10,078 | $10,000 | Not Implemented |
UM0163 # 08 Y:2000 | 08 | 2000 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $14,512 | $60,000 | Not Implemented |
UM0163 # 09 Y:2000 | 09 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $56,997 | $90,000 | Implemented |
GT0681 # 01 Y:1999 | 01 | 1999 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $10,162 | $0 | Not Implemented |
GT0681 # 02 Y:1999 | 02 | 1999 | ADJUST BURNERS FOR EFFICIENT OPERATION | $45,788 | $0 | Not Implemented |
GT0681 # 03 Y:1999 | 03 | 1999 | TREAT AND REUSE EQUIPMENT CLEANING SOLUTIONS | $6,800 | $0 | Not Implemented |
GT0681 # 04 Y:1999 | 04 | 1999 | USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER | $1,667 | $600 | Not Implemented |
GT0681 # 05 Y:1999 | 05 | 1999 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $12,917 | $4,800 | Implemented |
GT0681 # 06 Y:1999 | 06 | 1999 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $8,596 | $2,360 | Not Implemented |
GT0681 # 07 Y:1999 | 07 | 1999 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,970 | $1,950 | Not Implemented |
GT0681 # 08 Y:1999 | 08 | 1999 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $5,540 | $6,700 | Not Implemented |
GT0681 # 09 Y:1999 | 09 | 1999 | USE LESS WASTEFUL PACKAGING | $1,024 | $3,500 | Not Implemented |
GT0681 # 10 Y:1999 | 10 | 1999 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $125,800 | $64,000 | Not Implemented |
GT0681 # 11 Y:1999 | 11 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,431 | $57,365 | Not Implemented |