Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
111
matching recommendationsSIC | 335 | Nonferrous Rolling And Drawing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0487 # 04 Y:2020 | 04 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,784 | $10,912 | Not Implemented |
AS0487 # 05 Y:2020 | 05 | 2020 | USE PHOTOCELL CONTROLS | $12,092 | $5,188 | Not Implemented |
AS0487 # 01 Y:2020 | 01 | 2020 | INSTALL REFRIGERATION SYSTEM TO COOL PRODUCT | $502,983 | $7,794 | Not Implemented |
AS0487 # 03 Y:2020 | 03 | 2020 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $21,819 | $29,360 | Not Implemented |
AS0487 # 02 Y:2020 | 02 | 2020 | USE SOLAR HEAT TO MAKE ELECTRICTY | $51,986 | $394,050 | Not Implemented |
AS0458 # 03 Y:2018 | 03 | 2018 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $108,000 | $34,970 | Not Implemented |
AS0458 # 06 Y:2018 | 06 | 2018 | RECOVER AND REUSE COOLING WATER | $3,500 | $2,576 | Not Implemented |
AS0458 # 05 Y:2018 | 05 | 2018 | INSTALL SKYLIGHTS | $14,020 | $33,868 | Not Implemented |
AS0458 # 02 Y:2018 | 02 | 2018 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $141,718 | $198,093 | Not Implemented |
AS0458 # 07 Y:2018 | 07 | 2018 | COVER OPEN TANKS | $1,285 | $0 | Not Implemented |
AS0458 # 01 Y:2018 | 01 | 2018 | TURN OFF EQUIPMENT WHEN NOT IN USE | $229,273 | $13,000 | Implemented |
AS0458 # 08 Y:2018 | 08 | 2018 | AIR CONDITION ONLY SPACE NECESSARY | $713 | $312 | Not Implemented |
AS0458 # 04 Y:2018 | 04 | 2018 | USE SOLAR HEAT FOR HEAT | $15,016 | $6,034 | Not Implemented |
AS0383 # 10 Y:2004 | 10 | 2004 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $577,735 | $9,735 | Not Implemented |
AS0383 # 08 Y:2004 | 08 | 2004 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,942 | $600 | Not Implemented |
AS0383 # 01 Y:2004 | 01 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $842 | $200 | Not Implemented |
AS0383 # 03 Y:2004 | 03 | 2004 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $16,320 | $40,000 | Not Implemented |
AS0383 # 07 Y:2004 | 07 | 2004 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $244 | $600 | Not Implemented |
AS0383 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $21,498 | $120 | Not Implemented |
AS0383 # 04 Y:2004 | 04 | 2004 | INSTALL OCCUPANCY SENSORS | $2,878 | $1,350 | Not Implemented |
AS0383 # 09 Y:2004 | 09 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $406 | $367 | Not Implemented |
AS0383 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,064 | $12,003 | Not Implemented |
AS0383 # 06 Y:2004 | 06 | 2004 | COVER OPEN TANKS | $4,988 | $6,000 | Not Implemented |
AS0314 # 08 Y:2001 | 08 | 2001 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $1,055 | $40 | Implemented |
AS0314 # 01 Y:2001 | 01 | 2001 | INSTALL SKYLIGHTS | $474 | $996 | Implemented |