Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
149
matching recommendationsSIC | 3353 | Aluminum Sheet, Plate, And Foil |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0476 # 03 Y:2000 | 03 | 2000 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $2,310 | $1,000 | Implemented |
CO0476 # 04 Y:2000 | 04 | 2000 | USE EVAPORATION TO CONCENTRATE MATERIAL | $62,600 | $18,400 | Implemented |
CO0476 # 05 Y:2000 | 05 | 2000 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $16,290 | $13,500 | Not Implemented |
CO0476 # 06 Y:2000 | 06 | 2000 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $6,490 | $41,000 | Not Implemented |
NC0139 # 01 Y:1998 | 01 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $14,306 | $18,000 | Not Implemented |
NC0139 # 02 Y:1998 | 02 | 1998 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,424 | $1,800 | Implemented |
NC0139 # 03 Y:1998 | 03 | 1998 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $34,875 | $2,500 | Not Implemented |
NC0139 # 04 Y:1998 | 04 | 1998 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $5,815 | $25,000 | Not Implemented |
NC0139 # 05 Y:1998 | 05 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $42,277 | $70,000 | Not Implemented |
NC0139 # 06 Y:1998 | 06 | 1998 | USE OTHER WASTE CONCENTRATION METHODS | $4,704 | $4,000 | Not Implemented |
NC0139 # 07 Y:1998 | 07 | 1998 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $418,000 | $750,000 | Not Implemented |
UL0183 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,385 | $2,200 | Implemented |
UL0183 # 02 Y:1997 | 02 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $151 | $2,700 | Not Implemented |
UL0183 # 03 Y:1997 | 03 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,200 | $260 | Not Implemented |
UL0183 # 04 Y:1997 | 04 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $11,650 | $40 | Not Implemented |
UL0183 # 05 Y:1997 | 05 | 1997 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $40,200 | $82,600 | Not Implemented |
UL0183 # 06 Y:1997 | 06 | 1997 | CLEAR AND RENT EXISTING SPACE | $130,000 | $2,400 | Implemented |
AR0099 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,044 | $1,143 | Implemented |
AR0099 # 02 Y:1996 | 02 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,354 | $2,920 | Implemented |
AR0099 # 03 Y:1996 | 03 | 1996 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $13,886 | $13,040 | Implemented |
AR0099 # 04 Y:1996 | 04 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,537 | $200 | Implemented |
AR0099 # 05 Y:1996 | 05 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,300 | $0 | Not Implemented |
AR0099 # 06 Y:1996 | 06 | 1996 | MAINTAIN MACHINES TO REDUCE LEAKS | $7,300 | $600 | Implemented |
OK0437 # 01 Y:1994 | 01 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,582 | $0 | Implemented |
OK0437 # 02 Y:1994 | 02 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $4,255 | $5,951 | Not Implemented |