Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
768
matching recommendationsSIC | 3354 | Aluminum Extruded Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0233 # 05 Y:1999 | 05 | 1999 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $10,287 | $14,925 | Implemented |
UF0233 # 06 Y:1999 | 06 | 1999 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $33,600 | $0 | Implemented |
UF0233 # 07 Y:1999 | 07 | 1999 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $225 | $210 | Not Implemented |
GT0674 # 01 Y:1999 | 01 | 1999 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $45,500 | $60,000 | Not Implemented |
GT0674 # 02 Y:1999 | 02 | 1999 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $9,592 | $0 | Not Implemented |
GT0674 # 03 Y:1999 | 03 | 1999 | REPAIR AND ELIMINATE STEAM LEAKS | $4,037 | $400 | Implemented |
GT0674 # 04 Y:1999 | 04 | 1999 | INCREASE AMOUNT OF CONDENSATE RETURNED | $15,646 | $11,100 | Not Implemented |
GT0674 # 05 Y:1999 | 05 | 1999 | COVER OPEN TANKS | $22,910 | $13,671 | Not Implemented |
GT0674 # 06 Y:1999 | 06 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,892 | $14,981 | Implemented |
GT0674 # 07 Y:1999 | 07 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $419 | $100 | Implemented |
GT0674 # 08 Y:1999 | 08 | 1999 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $5,577 | $2,925 | Not Implemented |
GT0674 # 09 Y:1999 | 09 | 1999 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $20,189 | $0 | Not Implemented |
GT0674 # 10 Y:1999 | 10 | 1999 | MINIMIZE WATER USAGE | $12,618 | $0 | Not Implemented |
GT0674 # 11 Y:1999 | 11 | 1999 | INSTALL EQUIPMENT TO MOVE PRODUCT | $306,000 | $215,000 | Not Implemented |
HO0211 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,520 | $15,297 | Implemented |
HO0211 # 02 Y:1999 | 02 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,114 | $9,233 | Implemented |
HO0211 # 03 Y:1999 | 03 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,289 | $1,500 | Implemented |
HO0211 # 04 Y:1999 | 04 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,364 | $20 | Implemented |
HO0211 # 05 Y:1999 | 05 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $900 | $2,000 | Implemented |
HO0211 # 06 Y:1999 | 06 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,539 | $200 | Implemented |
HO0211 # 07 Y:1999 | 07 | 1999 | DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING | $969 | $1,400 | Not Implemented |
HO0211 # 08 Y:1999 | 08 | 1999 | USE COMPRESSOR AIR FILTERS | $6,130 | $150 | Implemented |
HO0211 # 09 Y:1999 | 09 | 1999 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,690 | $1,400 | Not Implemented |
HO0211 # 10 Y:1999 | 10 | 1999 | ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS | $15,600 | $480 | Implemented |
UM0127 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,907 | $5,428 | Not Implemented |