Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
768
matching recommendationsSIC | 3354 | Aluminum Extruded Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0127 # 02 Y:1999 | 02 | 1999 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $16,282 | $250 | Not Implemented |
UM0127 # 03 Y:1999 | 03 | 1999 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $11,496 | $5,000 | Not Implemented |
UM0127 # 04 Y:1999 | 04 | 1999 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $30,552 | $35,000 | Not Implemented |
UM0127 # 05 Y:1999 | 05 | 1999 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $12,705 | $13,600 | Not Implemented |
AS0229 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,509 | $12,941 | Not Implemented |
AS0229 # 02 Y:1998 | 02 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,979 | $200 | Implemented |
AS0229 # 03 Y:1998 | 03 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $16,030 | $56,554 | Implemented |
AS0229 # 04 Y:1998 | 04 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $352 | $435 | Implemented |
AS0229 # 05 Y:1998 | 05 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,538 | $16,808 | Not Implemented |
AS0229 # 06 Y:1998 | 06 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $14,691 | $300 | Not Implemented |
AS0229 # 07 Y:1998 | 07 | 1998 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $3,284 | $6,800 | Not Implemented |
AS0229 # 08 Y:1998 | 08 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $1,094 | $1,275 | Not Implemented |
AS0229 # 09 Y:1998 | 09 | 1998 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $1,718 | $450 | Implemented |
AS0229 # 10 Y:1998 | 10 | 1998 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $859 | $150 | Implemented |
AS0229 # 11 Y:1998 | 11 | 1998 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $4,584 | $60 | Not Implemented |
AS0229 # 12 Y:1998 | 12 | 1998 | MINIMIZE WATER USAGE | $945 | $400 | Not Implemented |
AS0229 # 13 Y:1998 | 13 | 1998 | USE ULTRASONIC CLEANING | $79,533 | $315,000 | Not Implemented |
AS0229 # 14 Y:1998 | 14 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $6,780 | $3,756 | Not Implemented |
AM0330 # 01 Y:1998 | 01 | 1998 | OPTIMIZE PLANT POWER FACTOR | $19,460 | $17,210 | Not Implemented |
AM0330 # 02 Y:1998 | 02 | 1998 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $4,820 | $0 | Implemented |
AM0330 # 03 Y:1998 | 03 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $4,560 | $100 | Implemented |
AM0330 # 04 Y:1998 | 04 | 1998 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $2,740 | $0 | Implemented |
AM0330 # 05 Y:1998 | 05 | 1998 | INSULATE BARE EQUIPMENT | $2,450 | $350 | Implemented |
AM0330 # 06 Y:1998 | 06 | 1998 | PAY UTILITY BILLS ON TIME | $1,938 | $0 | Implemented |
AM0330 # 07 Y:1998 | 07 | 1998 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $1,440 | $0 | Implemented |