Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
30
matching recommendationsSIC | 3354 | Aluminum Extruded Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0572 # 10 Y:2016 | 10 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $672 | $103 | Not Implemented |
NC0572 # 09 Y:2016 | 09 | 2016 | DEVELOP A REPAIR/REPLACE POLICY | $2,418 | $5,865 | Not Implemented |
NC0572 # 08 Y:2016 | 08 | 2016 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $117 | $180 | Not Implemented |
NC0572 # 07 Y:2016 | 07 | 2016 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $11,387 | $100 | Not Implemented |
NC0572 # 06 Y:2016 | 06 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $944 | $200 | Implemented |
NC0572 # 05 Y:2016 | 05 | 2016 | INSTALL OCCUPANCY SENSORS | $307 | $571 | Not Implemented |
NC0572 # 04 Y:2016 | 04 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,443 | $12,240 | Not Implemented |
NC0572 # 03 Y:2016 | 03 | 2016 | USE PHOTOCELL CONTROLS | $2,850 | $150 | Not Implemented |
NC0572 # 02 Y:2016 | 02 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,293 | $35,726 | Implemented |
NC0572 # 01 Y:2016 | 01 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,828 | $21,764 | Implemented |
NC0251 # 02 Y:2002 | 02 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $50,797 | $100,000 | Not Implemented |
NC0251 # 06 Y:2002 | 06 | 2002 | INSULATE BARE EQUIPMENT | $137 | $574 | Implemented |
NC0251 # 05 Y:2002 | 05 | 2002 | ADJUST BURNERS FOR EFFICIENT OPERATION | $4,768 | $10,000 | Implemented |
NC0251 # 04 Y:2002 | 04 | 2002 | REPLACE HIGH RESISTANCE DUCTS, PIPES, AND FITTINGS | $6,367 | $10,000 | Implemented |
NC0251 # 03 Y:2002 | 03 | 2002 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $4,593 | $7,000 | Not Implemented |
NC0251 # 01 Y:2002 | 01 | 2002 | INCREASE ELECTRICAL CONDUCTOR SIZE TO REDUCE DISTRIBUTION LOSSES | $29,079 | $130,000 | Not Implemented |
NC0045 # 08 Y:1994 | 08 | 1994 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $7,341 | $3,000 | Implemented |
NC0045 # 07 Y:1994 | 07 | 1994 | INSULATE BARE EQUIPMENT | $29,276 | $4,511 | Implemented |
NC0045 # 06 Y:1994 | 06 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,018 | $500 | Implemented |
NC0045 # 05 Y:1994 | 05 | 1994 | USE PHOTOCELL CONTROLS | $2,490 | $210 | Not Implemented |
NC0045 # 04 Y:1994 | 04 | 1994 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,312 | $720 | Not Implemented |
NC0045 # 03 Y:1994 | 03 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,943 | $630 | Implemented |
NC0045 # 02 Y:1994 | 02 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,703 | $2,581 | Not Implemented |
NC0045 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,193 | $5,730 | Not Implemented |
AT0039 # 01 Y:1986 | 01 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $834 | $859 | Implemented |