Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,079
matching recommendationsSIC | 336 | Nonferrous Foundries (castings) |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0509 # 08 Y:2006 | 08 | 2006 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,200 | $3,000 | Implemented |
WV0349 # 02 Y:2006 | 02 | 2006 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $48,286 | $39,350 | Implemented |
WV0349 # 03 Y:2006 | 03 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $14,527 | $640 | Implemented |
WV0349 # 04 Y:2006 | 04 | 2006 | REDUCE VENTILATION AIR | $13,672 | $10,295 | Implemented |
WV0349 # 07 Y:2006 | 07 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,242 | $400 | Implemented |
WV0349 # 08 Y:2006 | 08 | 2006 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $4,291 | $1,000 | Implemented |
WV0349 # 09 Y:2006 | 09 | 2006 | INSULATE BARE EQUIPMENT | $3,740 | $1,318 | Implemented |
WV0349 # 11 Y:2006 | 11 | 2006 | DEVELOP A REPAIR/REPLACE POLICY | $1,998 | $512 | Implemented |
WV0349 # 12 Y:2006 | 12 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $375 | $200 | Implemented |
UD0742 # 02 Y:2006 | 02 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $198,228 | $100,000 | Implemented |
UD0742 # 04 Y:2006 | 04 | 2006 | REDESIGN PROCESS | $174,377 | $0 | Implemented |
UD0742 # 09 Y:2006 | 09 | 2006 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $55,855 | $10,000 | Implemented |
UD0742 # 11 Y:2006 | 11 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $26,660 | $122,500 | Implemented |
UD0742 # 12 Y:2006 | 12 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $19,230 | $0 | Implemented |
UD0742 # 14 Y:2006 | 14 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $17,949 | $0 | Implemented |
UD0742 # 16 Y:2006 | 16 | 2006 | REDUCE WATER USE WITH COUNTER CURRENT RINSING | $7,083 | $0 | Implemented |
UD0742 # 18 Y:2006 | 18 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,020 | $0 | Implemented |
UD0742 # 19 Y:2006 | 19 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $874 | $867 | Implemented |
SU0237 # 03 Y:2006 | 03 | 2006 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,173 | $0 | Implemented |
SU0237 # 04 Y:2006 | 04 | 2006 | USE SYNTHETIC LUBRICANT | $606 | $0 | Implemented |
SU0237 # 06 Y:2006 | 06 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,115 | $219 | Implemented |
SU0237 # 07 Y:2006 | 07 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $660 | $220 | Implemented |
SU0237 # 08 Y:2006 | 08 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,224 | $7,782 | Implemented |
WI0519 # 02 Y:2006 | 02 | 2006 | IMPROVE SPACE COMFORT CONDITIONING | $30,000 | $1,800 | Implemented |
WI0519 # 04 Y:2006 | 04 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,299 | $0 | Implemented |