Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

53

matching recommendations
Reset
SIC 336 Nonferrous Foundries (castings)
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UC2207 # 05 Y:2022 05 2022 TURN OFF EQUIPMENT WHEN NOT IN USE $2,876 $500 Not Implemented
UC2207 # 04 Y:2022 04 2022 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,359 $2,800 Not Implemented
UC2207 # 06 Y:2022 06 2022 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS $4,478 $3,300 Not Implemented
UC2207 # 03 Y:2022 03 2022 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $12,731 $500 Not Implemented
UC2207 # 07 Y:2022 07 2022 USE SOLAR HEAT TO MAKE ELECTRICTY $70,713 $379,682 Not Implemented
UC2207 # 02 Y:2022 02 2022 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,727 $500 Not Implemented
UC2207 # 01 Y:2022 01 2022 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $378 $464 Not Implemented
MA0392 # 05 Y:1997 05 1997 CONVERT TO AQUEOUS CLEANING $276 $759 Implemented
MA0392 # 01 Y:1997 01 1997 MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE $34,500 $21,950 Implemented
MA0392 # 02 Y:1997 02 1997 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $8,500 $3,000 Not Implemented
MA0392 # 03 Y:1997 03 1997 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,388 $6,000 Not Implemented
MA0392 # 04 Y:1997 04 1997 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $320 $268 Implemented
MA0343 # 06 Y:1995 06 1995 COVER OPEN TANKS $828 $274 Implemented
MA0343 # 02 Y:1995 02 1995 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $8,446 $9,000 Not Implemented
MA0343 # 04 Y:1995 04 1995 ELIMINATE COMBUSTIBLE GAS IN FLUE GAS $2,131 $1,750 Not Implemented
MA0343 # 01 Y:1995 01 1995 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $26,616 $37,300 Not Implemented
MA0343 # 05 Y:1995 05 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,114 $6,330 Implemented
MA0343 # 03 Y:1995 03 1995 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,559 $3,300 Not Implemented
MA0325 # 01 Y:1995 01 1995 COVER OPEN TANKS $3,618 $1,883 Implemented
MA0325 # 04 Y:1995 04 1995 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,557 $1,000 Implemented
MA0325 # 09 Y:1995 09 1995 RECOVER METALS FROM SPENT SOLUTIONS AND RECYCLE $28,487 $53,330 Implemented
MA0325 # 10 Y:1995 10 1995 RECOVERY METALS FROM RINSE WATER(EVAP., ION EXCHANGE, RO, ELECTROLYSIS, ELECTRODIALYSIS) AND REUSE RINSE WATER $7,953 $5,526 Implemented
MA0325 # 06 Y:1995 06 1995 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $453 $1,190 Implemented
MA0325 # 03 Y:1995 03 1995 RECOVER WASTE HEAT FROM EQUIPMENT $1,545 $2,500 Not Implemented
MA0325 # 05 Y:1995 05 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $922 $0 Implemented