Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
122
matching recommendationsSIC | 336 | Nonferrous Foundries (castings) |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0172 # 06 Y:2000 | 06 | 2000 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $4,000 | $250 | Implemented |
UM0172 # 07 Y:2000 | 07 | 2000 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,500 | $3,000 | Not Implemented |
ND0358 # 01 Y:2000 | 01 | 2000 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $1,922 | $8,000 | Not Implemented |
ND0358 # 02 Y:2000 | 02 | 2000 | BURN A LESS EXPENSIVE GRADE OF FUEL | $11,307 | $39,100 | Not Implemented |
ND0358 # 03 Y:2000 | 03 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $164 | $400 | Not Implemented |
ND0358 # 04 Y:2000 | 04 | 2000 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $67 | $30 | Not Implemented |
ND0358 # 05 Y:2000 | 05 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,996 | $300 | Not Implemented |
ND0358 # 06 Y:2000 | 06 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,588 | $555 | Not Implemented |
ND0358 # 07 Y:2000 | 07 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,479 | $280 | Not Implemented |
ND0358 # 08 Y:2000 | 08 | 2000 | INSTALL OCCUPANCY SENSORS | $78 | $200 | Not Implemented |
UM0159 # 01 Y:2000 | 01 | 2000 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,800 | $200 | Implemented |
UM0159 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $172 | $50 | Implemented |
UM0159 # 03 Y:2000 | 03 | 2000 | ADJUST BURNERS FOR EFFICIENT OPERATION | $10,836 | $3,000 | Implemented |
UM0159 # 04 Y:2000 | 04 | 2000 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $4,390 | $4,000 | Implemented |
UM0159 # 05 Y:2000 | 05 | 2000 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $4,800 | $8,000 | Implemented |
UM0159 # 06 Y:2000 | 06 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $88,447 | $27,000 | Implemented |
UM0159 # 07 Y:2000 | 07 | 2000 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $95,726 | $35,000 | Not Implemented |
UM0142 # 01 Y:1999 | 01 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $416 | $450 | Implemented |
UM0142 # 02 Y:1999 | 02 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,691 | $1,250 | Implemented |
UM0142 # 03 Y:1999 | 03 | 1999 | TURN OFF EQUIPMENT WHEN NOT IN USE | $39 | $0 | Implemented |
UM0142 # 04 Y:1999 | 04 | 1999 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $55,979 | $38,958 | Not Implemented |
UM0142 # 05 Y:1999 | 05 | 1999 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $44,187 | $52,200 | Not Implemented |
UM0142 # 06 Y:1999 | 06 | 1999 | OPTIMIZE PLANT POWER FACTOR | $7,489 | $10,860 | Implemented |
UM0142 # 07 Y:1999 | 07 | 1999 | METER WASTE WATER | $6,412 | $500 | Implemented |
UM0142 # 08 Y:1999 | 08 | 1999 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $150,000 | $150,000 | Not Implemented |