Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
168
matching recommendationsSIC | 336 | Nonferrous Foundries (castings) |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0037 # 01 Y:2009 | 01 | 2009 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $87,552 | $18,000 | Not Implemented |
MZ0037 # 02 Y:2009 | 02 | 2009 | USE OPTIMUM THICKNESS INSULATION | $1,717 | $4,200 | Not Implemented |
MZ0037 # 03 Y:2009 | 03 | 2009 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $11,665 | $2,900 | Not Implemented |
MZ0037 # 04 Y:2009 | 04 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $739 | $850 | Not Implemented |
MZ0037 # 05 Y:2009 | 05 | 2009 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $710 | $1,993 | Not Implemented |
MZ0037 # 06 Y:2009 | 06 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $40,988 | $59,705 | Not Implemented |
MZ0037 # 07 Y:2009 | 07 | 2009 | INSTALL OCCUPANCY SENSORS | $490 | $640 | Not Implemented |
MZ0007 # 01 Y:2007 | 01 | 2007 | COVER OPEN TANKS | $2,560 | $0 | Implemented |
MZ0007 # 02 Y:2007 | 02 | 2007 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $10,000 | $20,000 | Not Implemented |
MZ0007 # 03 Y:2007 | 03 | 2007 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $533 | $0 | Implemented |
MZ0007 # 04 Y:2007 | 04 | 2007 | DISCONNECT BALLASTS | $27,567 | $1,310 | Implemented |
MZ0007 # 05 Y:2007 | 05 | 2007 | INSTALL OCCUPANCY SENSORS | $5,535 | $3,250 | Implemented |
MZ0001 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,357 | $20,580 | Not Implemented |
MZ0001 # 02 Y:2007 | 02 | 2007 | Hardware | $75,000 | $78,000 | Implemented |
MZ0001 # 03 Y:2007 | 03 | 2007 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $3,400 | $800 | Implemented |
MZ0001 # 04 Y:2007 | 04 | 2007 | Hardware | $24,000 | $78,000 | Not Implemented |
MZ0001 # 05 Y:2007 | 05 | 2007 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,915 | $3,300 | Implemented |
IA0389 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $394 | $344 | Not Implemented |
IA0389 # 02 Y:2006 | 02 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $376 | $42 | Not Implemented |
IA0389 # 03 Y:2006 | 03 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,332 | $322 | Not Implemented |
IA0389 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,671 | $4,008 | Not Implemented |
IA0389 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $848 | $1,836 | Not Implemented |
IA0389 # 06 Y:2006 | 06 | 2006 | INSTALL OCCUPANCY SENSORS | $667 | $77 | Not Implemented |
IA0389 # 07 Y:2006 | 07 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $493 | $305 | Not Implemented |
IA0389 # 08 Y:2006 | 08 | 2006 | ADJUST BURNERS FOR EFFICIENT OPERATION | $24,825 | $2,100 | Not Implemented |