Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,412
matching recommendationsSIC | 336 | Nonferrous Foundries (castings) |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0266 # 14 Y:2003 | 14 | 2003 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $39,573 | $0 | Implemented |
WV0266 # 15 Y:2003 | 15 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,178 | $80 | Not Implemented |
UD0665 # 01 Y:2003 | 01 | 2003 | RESCHEDULE BREAKS TO ALLOW FOR CONTINUOUS PRODUCTION | $380,000 | $38,587 | Not Implemented |
UD0665 # 02 Y:2003 | 02 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $74,995 | $40,000 | Not Implemented |
UD0665 # 03 Y:2003 | 03 | 2003 | INSULATE BARE EQUIPMENT | $14,021 | $1,545 | Not Implemented |
UD0665 # 04 Y:2003 | 04 | 2003 | COVER OPEN TANKS | $7,200 | $12,000 | Not Implemented |
UD0665 # 05 Y:2003 | 05 | 2003 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $4,325 | $0 | Implemented |
UD0665 # 06 Y:2003 | 06 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,561 | $8,112 | Implemented |
UD0665 # 07 Y:2003 | 07 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,363 | $6,762 | Not Implemented |
UD0665 # 08 Y:2003 | 08 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,130 | $1,000 | Not Implemented |
UD0665 # 09 Y:2003 | 09 | 2003 | DISCONNECT BALLASTS | $790 | $45 | Implemented |
UD0665 # 10 Y:2003 | 10 | 2003 | COVER OPEN TANKS | $256 | $400 | Implemented |
AS0345 # 01 Y:2003 | 01 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,950 | $30 | Implemented |
AS0345 # 02 Y:2003 | 02 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $294 | $30 | Not Implemented |
AS0345 # 03 Y:2003 | 03 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $519 | $3,755 | Implemented |
AS0345 # 04 Y:2003 | 04 | 2003 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $2,428 | $8,500 | Implemented |
AS0345 # 05 Y:2003 | 05 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $216 | $89 | Implemented |
AS0345 # 06 Y:2003 | 06 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $209 | $49 | Implemented |
AS0345 # 07 Y:2003 | 07 | 2003 | USE SYNTHETIC LUBRICANT | $420 | $3,231 | Not Implemented |
AS0345 # 08 Y:2003 | 08 | 2003 | INSTALL EQUIPMENT TO MOVE PRODUCT | $16,133 | $825 | Not Implemented |
AS0345 # 09 Y:2003 | 09 | 2003 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $15,623 | $5,760 | Not Implemented |
AS0345 # 10 Y:2003 | 10 | 2003 | CLEAR AND RENT EXISTING SPACE | $11,984 | $9,060 | Not Implemented |
AS0345 # 11 Y:2003 | 11 | 2003 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $910 | $960 | Not Implemented |
LM0047 # 01 Y:2003 | 01 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $9,457 | $6,432 | Not Implemented |
LM0047 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,703 | $200 | Implemented |