Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,412
matching recommendationsSIC | 336 | Nonferrous Foundries (castings) |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0190 # 05 Y:2000 | 05 | 2000 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $920 | $850 | Not Implemented |
WV0190 # 06 Y:2000 | 06 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,883 | $780 | Implemented |
WV0190 # 07 Y:2000 | 07 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $63,174 | $66,000 | Implemented |
WV0190 # 08 Y:2000 | 08 | 2000 | INSTALL SPECTRAL REFLECTORS / DELAMP | $2,768 | $2,868 | Not Implemented |
WV0190 # 09 Y:2000 | 09 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $22,514 | $30 | Not Implemented |
WV0190 # 10 Y:2000 | 10 | 2000 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $52,195 | $13,550 | Not Implemented |
WV0190 # 11 Y:2000 | 11 | 2000 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $66,820 | $78,000 | Implemented |
WV0190 # 12 Y:2000 | 12 | 2000 | INSTALL SENSORS TO DETECT DEFECTS | $1,785,600 | $2,400,000 | Not Implemented |
WV0190 # 13 Y:2000 | 13 | 2000 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $15,000 | $6,240 | Not Implemented |
UM0159 # 01 Y:2000 | 01 | 2000 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,800 | $200 | Implemented |
UM0159 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $172 | $50 | Implemented |
UM0159 # 03 Y:2000 | 03 | 2000 | ADJUST BURNERS FOR EFFICIENT OPERATION | $10,836 | $3,000 | Implemented |
UM0159 # 04 Y:2000 | 04 | 2000 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $4,390 | $4,000 | Implemented |
UM0159 # 05 Y:2000 | 05 | 2000 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $4,800 | $8,000 | Implemented |
UM0159 # 06 Y:2000 | 06 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $88,447 | $27,000 | Implemented |
UM0159 # 07 Y:2000 | 07 | 2000 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $95,726 | $35,000 | Not Implemented |
BD0157 # 01 Y:2000 | 01 | 2000 | USE RADIANT HEATER FOR SPOT HEATING | $3,147 | $2,325 | Not Implemented |
BD0157 # 02 Y:2000 | 02 | 2000 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $2,952 | $4,600 | Not Implemented |
BD0157 # 03 Y:2000 | 03 | 2000 | INSTALL OCCUPANCY SENSORS | $1,314 | $825 | Implemented |
BD0157 # 04 Y:2000 | 04 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $507 | $1,500 | Not Implemented |
BD0157 # 05 Y:2000 | 05 | 2000 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $19,669 | $800 | Implemented |
BD0157 # 06 Y:2000 | 06 | 2000 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $9,601 | $11,200 | Implemented |
BD0157 # 07 Y:2000 | 07 | 2000 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $4,141 | $3,250 | Not Implemented |
ND0343 # 01 Y:2000 | 01 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $27,009 | $4,500 | Not Implemented |
ND0343 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,145 | $400 | Not Implemented |