Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
78
matching recommendationsSIC | 336 | Nonferrous Foundries (castings) |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0026 # 08 Y:2008 | 08 | 2008 | OPTIMIZE PLANT POWER FACTOR | $1,150 | $6,000 | Not Implemented |
TT0026 # 07 Y:2008 | 07 | 2008 | INSULATE BARE EQUIPMENT | $25,000 | $1,000 | Not Implemented |
TT0026 # 06 Y:2008 | 06 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,000 | $4,900 | Not Implemented |
TT0026 # 05 Y:2008 | 05 | 2008 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $16,119 | $55,000 | Not Implemented |
TT0026 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $190 | $590 | Not Implemented |
TT0026 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,430 | $3,640 | Not Implemented |
TT0026 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,980 | $6,600 | Not Implemented |
TT0026 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $67,300 | $63,800 | Not Implemented |
UF0413 # 04 Y:2008 | 04 | 2008 | INSTALL OCCUPANCY SENSORS | $1,150 | $219 | Implemented |
UF0413 # 01 Y:2008 | 01 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,814 | $810 | Implemented |
UF0413 # 09 Y:2008 | 09 | 2008 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $151,840 | $16,695 | Not Implemented |
UF0413 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $34,500 | $54,000 | Implemented |
UF0413 # 06 Y:2008 | 06 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $13,321 | $13,321 | Implemented |
UF0413 # 08 Y:2008 | 08 | 2008 | INSTALL COMMON HEADER ON COMPRESSORS | $871 | $2,000 | Implemented |
UF0413 # 03 Y:2008 | 03 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,206 | $16,270 | Not Implemented |
UF0413 # 10 Y:2008 | 10 | 2008 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $9,571 | $1,500 | Not Implemented |
UF0413 # 05 Y:2008 | 05 | 2008 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $14,800 | $1,117 | Implemented |
UF0413 # 07 Y:2008 | 07 | 2008 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $12,742 | $20,000 | Not Implemented |
UW0018 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,037 | $2,775 | Not Implemented |
UW0018 # 01 Y:2008 | 01 | 2008 | UTILIZE JOB COSTING SOFTWARE | $55,734 | $72,000 | Not Implemented |
UW0018 # 04 Y:2008 | 04 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,375 | $4,328 | Not Implemented |
UW0018 # 03 Y:2008 | 03 | 2008 | USE OPTIMUM THICKNESS INSULATION | $9,391 | $39,900 | Not Implemented |
UW0018 # 02 Y:2008 | 02 | 2008 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $12,434 | $34,000 | Not Implemented |
BD0346 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $84,447 | $2,972 | Implemented |
BD0346 # 02 Y:2008 | 02 | 2008 | INSTALL OCCUPANCY SENSORS | $1,472 | $676 | Not Implemented |