Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
503
matching recommendationsSIC | 3363 | Aluminum Die-castings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0154 # 05 Y:1993 | 05 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,112 | $200 | Implemented |
ND0154 # 06 Y:1993 | 06 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $638 | $200 | Implemented |
ND0154 # 07 Y:1993 | 07 | 1993 | DISCONNECT BALLASTS | $193 | $200 | Implemented |
TN0490 # 02 Y:1993 | 02 | 1993 | ISOLATE HOT OR COLD EQUIPMENT | $2,687 | $7,200 | Implemented |
TN0490 # 03 Y:1993 | 03 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,097 | $490 | Implemented |
TN0490 # 04 Y:1993 | 04 | 1993 | INSTALL TIMERS AND/OR THERMOSTATS | $746 | $460 | Implemented |
IA0045 # 01 Y:1993 | 01 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,690 | $660 | Implemented |
IA0045 # 03 Y:1993 | 03 | 1993 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $4,196 | $2,893 | Implemented |
RU0153 # 01 Y:1992 | 01 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,182 | $750 | Implemented |
RU0153 # 02 Y:1992 | 02 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $309 | $0 | Implemented |
RU0153 # 03 Y:1992 | 03 | 1992 | INSTALL SET-BACK TIMERS | $865 | $199 | Implemented |
RU0153 # 08 Y:1992 | 08 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,657 | $2,500 | Implemented |
WI0153 # 03 Y:1992 | 03 | 1992 | OPTIMIZE PLANT POWER FACTOR | $5,209 | $9,758 | Implemented |
MA0250 # 02 Y:1992 | 02 | 1992 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $39,404 | $1,280 | Implemented |
MA0250 # 05 Y:1992 | 05 | 1992 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $1,289 | $0 | Implemented |
TN0457 # 03 Y:1992 | 03 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,886 | $210 | Implemented |
UD0364 # 04 Y:1992 | 04 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,121 | $14,430 | Implemented |
WI0084 # 02 Y:1990 | 02 | 1990 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,910 | $2,000 | Implemented |
WI0084 # 03 Y:1990 | 03 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $705 | $1,328 | Implemented |
WI0084 # 04 Y:1990 | 04 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $930 | $2,000 | Implemented |
WI0084 # 06 Y:1990 | 06 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $478 | $250 | Implemented |
RU0084 # 01 Y:1990 | 01 | 1990 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $68,217 | $70,000 | Implemented |
WI0048 # 01 Y:1989 | 01 | 1989 | IMPROVE LUBRICATION PRACTICES | $6,089 | $0 | Implemented |
WI0048 # 03 Y:1989 | 03 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,825 | $2,925 | Implemented |
WI0048 # 07 Y:1989 | 07 | 1989 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $136,661 | $0 | Implemented |