Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
60
matching recommendationsSIC | 3363 | Aluminum Die-castings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0193 # 11 Y:2001 | 11 | 2001 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $27,400 | $1,000 | Implemented |
UM0193 # 12 Y:2001 | 12 | 2001 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $26,010 | $1,650 | Not Implemented |
UM0193 # 13 Y:2001 | 13 | 2001 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $4,000 | $4,200 | Not Implemented |
UM0182 # 03 Y:2001 | 03 | 2001 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $57,900 | $28,900 | Implemented |
UM0182 # 04 Y:2001 | 04 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $43,000 | $100,000 | Not Implemented |
UM0182 # 02 Y:2001 | 02 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $361 | $1,000 | Not Implemented |
UM0182 # 01 Y:2001 | 01 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $568 | $375 | Implemented |
UM0159 # 07 Y:2000 | 07 | 2000 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $95,726 | $35,000 | Not Implemented |
UM0159 # 06 Y:2000 | 06 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $88,447 | $27,000 | Implemented |
UM0159 # 05 Y:2000 | 05 | 2000 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $4,800 | $8,000 | Implemented |
UM0159 # 04 Y:2000 | 04 | 2000 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $4,390 | $4,000 | Implemented |
UM0159 # 03 Y:2000 | 03 | 2000 | ADJUST BURNERS FOR EFFICIENT OPERATION | $10,836 | $3,000 | Implemented |
UM0159 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $172 | $50 | Implemented |
UM0159 # 01 Y:2000 | 01 | 2000 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,800 | $200 | Implemented |
UM0142 # 03 Y:1999 | 03 | 1999 | TURN OFF EQUIPMENT WHEN NOT IN USE | $39 | $0 | Implemented |
UM0142 # 01 Y:1999 | 01 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $416 | $450 | Implemented |
UM0142 # 02 Y:1999 | 02 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,691 | $1,250 | Implemented |
UM0142 # 04 Y:1999 | 04 | 1999 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $55,979 | $38,958 | Not Implemented |
UM0142 # 06 Y:1999 | 06 | 1999 | OPTIMIZE PLANT POWER FACTOR | $7,489 | $10,860 | Implemented |
UM0142 # 07 Y:1999 | 07 | 1999 | METER WASTE WATER | $6,412 | $500 | Implemented |
UM0142 # 08 Y:1999 | 08 | 1999 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $150,000 | $150,000 | Not Implemented |
UM0142 # 05 Y:1999 | 05 | 1999 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $44,187 | $52,200 | Not Implemented |
UM0060 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,561 | $12,818 | Not Implemented |
UM0060 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,500 | $1,607 | Implemented |
UM0060 # 03 Y:1996 | 03 | 1996 | OPTIMIZE PLANT POWER FACTOR | $2,418 | $6,182 | Not Implemented |