Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,106

matching recommendations
Reset
SIC 3363 Aluminum Die-castings
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UL0184 # 05 Y:1997 05 1997 OPTIMIZE PLANT POWER FACTOR $6,000 $9,270 Implemented
UL0184 # 06 Y:1997 06 1997 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $10,630 $20,000 Not Implemented
UL0184 # 07 Y:1997 07 1997 TURN OFF EQUIPMENT WHEN NOT IN USE $4,146 $0 Implemented
UL0184 # 08 Y:1997 08 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,090 $1,200 Implemented
UL0184 # 09 Y:1997 09 1997 REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY $4,400 $0 Not Implemented
UL0184 # 10 Y:1997 10 1997 USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL $21,700 $18,000 Not Implemented
UL0184 # 11 Y:1997 11 1997 $315,748 $222,000 Implemented
UL0184 # 12 Y:1997 12 1997 $110,952 $61,340 Not Implemented
UL0184 # 13 Y:1997 13 1997 $21,714 $4,200 Implemented
WI0295 # 01 Y:1997 01 1997 $119,785 $0 n/a
WI0295 # 02 Y:1997 02 1997 $68,700 $0 n/a
WI0295 # 03 Y:1997 03 1997 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $14,566 $0 n/a
WI0295 # 04 Y:1997 04 1997 REPLACE CLOTH RAGS WITH PAPER TOWELS $6,488 $10,000 n/a
WI0295 # 05 Y:1997 05 1997 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $822 $1,010 n/a
WI0295 # 06 Y:1997 06 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $807 $500 n/a
WI0295 # 07 Y:1997 07 1997 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $617 $0 n/a
WI0295 # 08 Y:1997 08 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $453 $0 n/a
UM0060 # 01 Y:1996 01 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,500 $1,607 Implemented
UM0060 # 02 Y:1996 02 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,561 $12,818 Not Implemented
UM0060 # 03 Y:1996 03 1996 OPTIMIZE PLANT POWER FACTOR $2,418 $6,182 Not Implemented
UM0060 # 04 Y:1996 04 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,807 $2,550 Implemented
UM0060 # 05 Y:1996 05 1996 TREAT AND REUSE RINSE WATERS $1,039 $1,000 Implemented
NC0082 # 01 Y:1996 01 1996 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $1,228 $2,500 Implemented
NC0082 # 02 Y:1996 02 1996 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $1,084 $3,000 Not Implemented
NC0082 # 03 Y:1996 03 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $534 $330 Not Implemented