Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,106
matching recommendationsSIC | 3363 | Aluminum Die-castings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UL0184 # 05 Y:1997 | 05 | 1997 | OPTIMIZE PLANT POWER FACTOR | $6,000 | $9,270 | Implemented |
UL0184 # 06 Y:1997 | 06 | 1997 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $10,630 | $20,000 | Not Implemented |
UL0184 # 07 Y:1997 | 07 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,146 | $0 | Implemented |
UL0184 # 08 Y:1997 | 08 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,090 | $1,200 | Implemented |
UL0184 # 09 Y:1997 | 09 | 1997 | REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY | $4,400 | $0 | Not Implemented |
UL0184 # 10 Y:1997 | 10 | 1997 | USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL | $21,700 | $18,000 | Not Implemented |
UL0184 # 11 Y:1997 | 11 | 1997 | AUTOMATE FINISHING PROCESS | $315,748 | $222,000 | Implemented |
UL0184 # 12 Y:1997 | 12 | 1997 | DEVELOP STANDARD OPERATING PROCEDURES | $110,952 | $61,340 | Not Implemented |
UL0184 # 13 Y:1997 | 13 | 1997 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $21,714 | $4,200 | Implemented |
WI0295 # 01 Y:1997 | 01 | 1997 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $119,785 | $0 | n/a |
WI0295 # 02 Y:1997 | 02 | 1997 | MAINTAIN/ENLARGE A STOCK OF SPARE PARTS | $68,700 | $0 | n/a |
WI0295 # 03 Y:1997 | 03 | 1997 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $14,566 | $0 | n/a |
WI0295 # 04 Y:1997 | 04 | 1997 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $6,488 | $10,000 | n/a |
WI0295 # 05 Y:1997 | 05 | 1997 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $822 | $1,010 | n/a |
WI0295 # 06 Y:1997 | 06 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $807 | $500 | n/a |
WI0295 # 07 Y:1997 | 07 | 1997 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $617 | $0 | n/a |
WI0295 # 08 Y:1997 | 08 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $453 | $0 | n/a |
UM0060 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,500 | $1,607 | Implemented |
UM0060 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,561 | $12,818 | Not Implemented |
UM0060 # 03 Y:1996 | 03 | 1996 | OPTIMIZE PLANT POWER FACTOR | $2,418 | $6,182 | Not Implemented |
UM0060 # 04 Y:1996 | 04 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,807 | $2,550 | Implemented |
UM0060 # 05 Y:1996 | 05 | 1996 | TREAT AND REUSE RINSE WATERS | $1,039 | $1,000 | Implemented |
NC0082 # 01 Y:1996 | 01 | 1996 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $1,228 | $2,500 | Implemented |
NC0082 # 02 Y:1996 | 02 | 1996 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,084 | $3,000 | Not Implemented |
NC0082 # 03 Y:1996 | 03 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $534 | $330 | Not Implemented |