Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,106
matching recommendationsSIC | 3363 | Aluminum Die-castings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IP0031 # 01 Y:2014 | 01 | 2014 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $5,065,497 | $375,000 | Not Implemented |
IP0031 # 02 Y:2014 | 02 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $22,715 | $14,486 | Implemented |
IP0031 # 03 Y:2014 | 03 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,679 | $59,914 | Implemented |
IP0031 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,588 | $22,450 | Implemented |
IP0031 # 05 Y:2014 | 05 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,661,000 | $17,500,000 | Not Implemented |
WM0052 # 01 Y:2014 | 01 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $71,098 | $51,000 | Not Implemented |
WM0052 # 02 Y:2014 | 02 | 2014 | USE OPTIMUM TEMPERATURE | $55,730 | $0 | Not Implemented |
WM0052 # 03 Y:2014 | 03 | 2014 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $44,848 | $200,000 | Not Implemented |
WM0052 # 04 Y:2014 | 04 | 2014 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $7,464 | $602 | Implemented |
WM0052 # 05 Y:2014 | 05 | 2014 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,689 | $608 | Not Implemented |
WM0052 # 06 Y:2014 | 06 | 2014 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $6,489 | $9,750 | Not Implemented |
WM0052 # 07 Y:2014 | 07 | 2014 | INSULATE BARE EQUIPMENT | $2,595 | $2,500 | Not Implemented |
WM0052 # 08 Y:2014 | 08 | 2014 | INSTALL OCCUPANCY SENSORS | $391 | $375 | Implemented |
UA0126 # 01 Y:2014 | 01 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $57,076 | $122,855 | Not Implemented |
UA0126 # 02 Y:2014 | 02 | 2014 | DISCONNECT BALLASTS | $14,055 | $1,200 | Not Implemented |
UA0126 # 03 Y:2014 | 03 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $8,580 | $6,440 | Not Implemented |
UA0126 # 04 Y:2014 | 04 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,605 | $6,195 | Not Implemented |
UA0126 # 05 Y:2014 | 05 | 2014 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $3,304 | $583 | Implemented |
UA0126 # 06 Y:2014 | 06 | 2014 | INSTALL TIMERS AND/OR THERMOSTATS | $4,317 | $625 | Implemented |
UA0126 # 07 Y:2014 | 07 | 2014 | OPTIMIZE PLANT POWER FACTOR | $19,245 | $19,520 | Not Implemented |
MZ0152 # 01 Y:2014 | 01 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,003 | $9,000 | Implemented |
MZ0152 # 02 Y:2014 | 02 | 2014 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $833 | $690 | Implemented |
MZ0152 # 03 Y:2014 | 03 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $14,092 | $1,160 | Implemented |
MZ0152 # 04 Y:2014 | 04 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,587 | $1,600 | Not Implemented |
MZ0152 # 05 Y:2014 | 05 | 2014 | INSULATE BARE EQUIPMENT | $9,287 | $9,958 | Not Implemented |