Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

646

matching recommendations
Reset
SIC 3365 Aluminum Foundries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0254 # 08 Y:2000 08 2000 $1,992 $0 Implemented
ND0343 # 01 Y:2000 01 2000 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $27,009 $4,500 Not Implemented
ND0343 # 02 Y:2000 02 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,145 $400 Not Implemented
ND0343 # 03 Y:2000 03 2000 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $507 $40 Not Implemented
ND0343 # 04 Y:2000 04 2000 DEVELOP A REPAIR/REPLACE POLICY $8,389 $43,959 Not Implemented
ND0343 # 05 Y:2000 05 2000 OPTIMIZE PLANT POWER FACTOR $11,327 $22,922 Not Implemented
ND0343 # 06 Y:2000 06 2000 $-3,501 $6,210 Not Implemented
ND0343 # 07 Y:2000 07 2000 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $24,533 $250 Not Implemented
UD0573 # 01 Y:1999 01 1999 $238,622 $0 Implemented
UD0573 # 02 Y:1999 02 1999 RECYCLE CASTING SAND $159,120 $310,000 Implemented
UD0573 # 03 Y:1999 03 1999 PREHEAT COMBUSTION AIR WITH WASTE HEAT $30,590 $30,500 Not Implemented
UD0573 # 04 Y:1999 04 1999 RECOVER WASTE HEAT FROM EQUIPMENT $10,431 $6,000 Not Implemented
UD0573 # 05 Y:1999 05 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,523 $14,669 Implemented
UD0573 # 06 Y:1999 06 1999 USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER $1,294 $200 Not Implemented
UD0538 # 01 Y:1998 01 1998 IMPLEMENT A MAINTENANCE PROGRAM TO KEEP RACKS AND TANKS FREE OF RUST, CRACKS, OR CORROSION $211,528 $50,000 Implemented
UD0538 # 02 Y:1998 02 1998 $44,426 $3,000 Not Implemented
UD0538 # 03 Y:1998 03 1998 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $8,377 $-10,000 Not Implemented
UD0538 # 04 Y:1998 04 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,771 $5,737 Implemented
UD0515 # 01 Y:1997 01 1997 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $36,109 $60,000 Implemented
UD0515 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,688 $11,020 Not Implemented
UD0515 # 03 Y:1997 03 1997 CONSOLIDATE FREIGHT SHIPMENTS AND/OR DELIVERIES $34,031 $25,000 Not Implemented
UD0515 # 04 Y:1997 04 1997 $67,125 $2,500 Not Implemented
UD0515 # 05 Y:1997 05 1997 $19,500 $8,000 Not Implemented
UD0515 # 06 Y:1997 06 1997 USE OTHER METHODS FOR NEUTRALIZATION $5,655 $500 Not Implemented
UD0515 # 07 Y:1997 07 1997 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $2,789 $200 Implemented