Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
673
matching recommendationsSIC | 3365 | Aluminum Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0873 # 04 Y:2014 | 04 | 2014 | USE RADIANT HEATER FOR SPOT HEATING | $21,894 | $7,500 | Not Implemented |
OK0873 # 05 Y:2014 | 05 | 2014 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $100,171 | $14,950 | Not Implemented |
OK0873 # 06 Y:2014 | 06 | 2014 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $102,361 | $450,000 | Implemented |
OK0873 # 07 Y:2014 | 07 | 2014 | COVER OPEN TANKS | $9,771 | $0 | Implemented |
OK0873 # 08 Y:2014 | 08 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $24,004 | $63,370 | Not Implemented |
OK0873 # 09 Y:2014 | 09 | 2014 | OPTIMIZE PLANT POWER FACTOR | $9,509 | $11,638 | Not Implemented |
MZ0120 # 04 Y:2013 | 04 | 2013 | INSTALL OCCUPANCY SENSORS | $153 | $190 | Implemented |
MZ0120 # 05 Y:2013 | 05 | 2013 | USE COMPRESSOR AIR FILTERS | $4,675 | $1,100 | Implemented |
MZ0120 # 01 Y:2013 | 01 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $28,136 | $119,770 | Implemented |
MZ0120 # 02 Y:2013 | 02 | 2013 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $35,241 | $75,000 | Not Implemented |
MZ0120 # 03 Y:2013 | 03 | 2013 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $8,557 | $31,200 | Implemented |
MZ0110 # 01 Y:2013 | 01 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $7,869 | $3,480 | Implemented |
MZ0110 # 02 Y:2013 | 02 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,761 | $39,840 | Implemented |
MZ0110 # 03 Y:2013 | 03 | 2013 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $90,000 | $97,500 | Implemented |
MZ0110 # 04 Y:2013 | 04 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $21,089 | $6,600 | Not Implemented |
MZ0110 # 05 Y:2013 | 05 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $12,710 | $0 | Not Implemented |
MZ0110 # 06 Y:2013 | 06 | 2013 | USE COMPRESSOR AIR FILTERS | $4,048 | $2,400 | Implemented |
MZ0095 # 01 Y:2012 | 01 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $199 | $640 | Implemented |
MZ0095 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,134 | $5,290 | Implemented |
MZ0095 # 03 Y:2012 | 03 | 2012 | REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY | $688 | $0 | Implemented |
MZ0095 # 04 Y:2012 | 04 | 2012 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $7,949 | $1,660 | Not Implemented |
UK1211 # 01 Y:2012 | 01 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $12,859 | $11,250 | Not Implemented |
UK1211 # 02 Y:2012 | 02 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $940 | $420 | Not Implemented |
UK1211 # 03 Y:2012 | 03 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,299 | $7,500 | Not Implemented |
UK1211 # 04 Y:2012 | 04 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,517 | $30,800 | Not Implemented |