Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
310
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD1027 # 09 Y:2021 | 09 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,013 | $65,250 | Implemented |
UD1027 # 10 Y:2021 | 10 | 2021 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $10,735 | $43,000 | Not Implemented |
AS0510 # 01 Y:2021 | 01 | 2021 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $18,281 | $200 | Not Implemented |
AS0510 # 02 Y:2021 | 02 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,025 | $18,448 | Not Implemented |
AS0510 # 03 Y:2021 | 03 | 2021 | INSTALL SPECTRAL REFLECTORS / DELAMP | $13,978 | $9,244 | Implemented |
AS0510 # 04 Y:2021 | 04 | 2021 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $7,800 | $453 | Not Implemented |
AS0510 # 05 Y:2021 | 05 | 2021 | INSTALL HEAT PIPES / RAISE COOLING SETPOINT | $6,879 | $560 | Not Implemented |
AS0510 # 06 Y:2021 | 06 | 2021 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,097 | $447 | Not Implemented |
AS0510 # 07 Y:2021 | 07 | 2021 | UPGRADE CONTROLS ON COMPRESSORS | $713 | $3,359 | Implemented |
AS0510 # 08 Y:2021 | 08 | 2021 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $690 | $40 | Not Implemented |
LE0503 # 01 Y:2021 | 01 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $21,633 | $50,000 | Implemented |
LE0503 # 02 Y:2021 | 02 | 2021 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $11,108 | $45,000 | Implemented |
LE0503 # 03 Y:2021 | 03 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,254 | $17,500 | Implemented |
LE0503 # 04 Y:2021 | 04 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,126 | $15,100 | Implemented |
LE0503 # 05 Y:2021 | 05 | 2021 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $56,981 | $300,000 | Implemented |
NC0656 # 01 Y:2021 | 01 | 2021 | RECOVER WASTE HEAT FROM EQUIPMENT | $21,457 | $44,289 | n/a |
NC0656 # 02 Y:2021 | 02 | 2021 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $39,666 | $500 | n/a |
NC0656 # 03 Y:2021 | 03 | 2021 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $10,304 | $2,048 | n/a |
NC0656 # 04 Y:2021 | 04 | 2021 | USE SOLAR HEAT TO MAKE ELECTRICTY | $13,212 | $111,000 | n/a |
NL0054 # 01 Y:2021 | 01 | 2021 | OPTIMIZE PLANT POWER FACTOR | $16,506 | $12,500 | Not Implemented |
NL0054 # 02 Y:2021 | 02 | 2021 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $8,000 | $16,000 | Not Implemented |
NL0054 # 03 Y:2021 | 03 | 2021 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $7,166 | $12,910 | Not Implemented |
NL0054 # 04 Y:2021 | 04 | 2021 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,837 | $18,456 | Not Implemented |
NL0054 # 05 Y:2021 | 05 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,098 | $4,000 | Not Implemented |
NL0054 # 06 Y:2021 | 06 | 2021 | ISOLATE HOT OR COLD EQUIPMENT | $3,823 | $1,018 | Not Implemented |