Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
595
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0453 # 04 Y:2003 | 04 | 2003 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $3,824 | $8,700 | Not Implemented |
WI0453 # 05 Y:2003 | 05 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,121 | $1,280 | Implemented |
WI0453 # 06 Y:2003 | 06 | 2003 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $4,657 | $20,000 | Not Implemented |
WI0442 # 02 Y:2003 | 02 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $16,332 | $6,498 | Not Implemented |
WI0442 # 03 Y:2003 | 03 | 2003 | USE POWER DURING OFF-PEAK PERIODS | $5,132 | $0 | Not Implemented |
WI0442 # 04 Y:2003 | 04 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,640 | $10,000 | Not Implemented |
WI0442 # 05 Y:2003 | 05 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,559 | $500 | Not Implemented |
WI0442 # 01 Y:2003 | 01 | 2003 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $188,665 | $146,300 | Not Implemented |
WI0441 # 01 Y:2003 | 01 | 2003 | INCREASE USE OF AUTOMATION | $66,563 | $30,000 | Not Implemented |
WI0441 # 02 Y:2003 | 02 | 2003 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $5,650 | $16,800 | Implemented |
WI0441 # 03 Y:2003 | 03 | 2003 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $2,550 | $0 | Implemented |
WI0441 # 04 Y:2003 | 04 | 2003 | USE POWER DURING OFF-PEAK PERIODS | $1,486 | $0 | Not Implemented |
WI0441 # 05 Y:2003 | 05 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $168 | $640 | Not Implemented |
WI0440 # 01 Y:2003 | 01 | 2003 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $3,066 | $0 | Not Implemented |
WI0440 # 02 Y:2003 | 02 | 2003 | ADJUST BURNERS FOR EFFICIENT OPERATION | $1,887 | $500 | Not Implemented |
WI0440 # 03 Y:2003 | 03 | 2003 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $700 | $100 | Not Implemented |
WI0440 # 04 Y:2003 | 04 | 2003 | INSTALL OCCUPANCY SENSORS | $617 | $2,400 | Not Implemented |
WI0440 # 05 Y:2003 | 05 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $185 | $102 | Not Implemented |
WI0440 # 06 Y:2003 | 06 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $122 | $0 | Not Implemented |
WI0439 # 01 Y:2003 | 01 | 2003 | INSTALL OCCUPANCY SENSORS | $2,581 | $5,500 | Implemented |
WI0439 # 02 Y:2003 | 02 | 2003 | INSTALL OCCUPANCY SENSORS | $537 | $75 | Not Implemented |
WI0439 # 03 Y:2003 | 03 | 2003 | INSTALL OCCUPANCY SENSORS | $2,560 | $9,600 | Not Implemented |
WI0439 # 04 Y:2003 | 04 | 2003 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,921 | $608 | Not Implemented |
WI0439 # 05 Y:2003 | 05 | 2003 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $1,726 | $0 | Not Implemented |
WI0439 # 06 Y:2003 | 06 | 2003 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,084 | $1,200 | Not Implemented |