Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
568
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0118 # 05 Y:2001 | 05 | 2001 | ELIMINATE SHIFT | $20,861 | $0 | Not Implemented |
SU0106 # 01 Y:2001 | 01 | 2001 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $10,051 | $0 | Implemented |
SU0106 # 02 Y:2001 | 02 | 2001 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $399,407 | $1,400,000 | Not Implemented |
SU0106 # 03 Y:2001 | 03 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,947 | $2,241 | Not Implemented |
SU0106 # 04 Y:2001 | 04 | 2001 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,158 | $500 | Implemented |
SU0106 # 05 Y:2001 | 05 | 2001 | OPTIMIZE PLANT POWER FACTOR | $3,243 | $10,210 | Implemented |
HO0195 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,672 | $9,033 | Not Implemented |
HO0195 # 02 Y:1999 | 02 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,258 | $150 | Not Implemented |
HO0195 # 03 Y:1999 | 03 | 1999 | AIR CONDITION ONLY SPACE NECESSARY | $2,914 | $0 | Not Implemented |
HO0195 # 04 Y:1999 | 04 | 1999 | IMPROVE SPACE COMFORT CONDITIONING | $960 | $3,000 | Not Implemented |
HO0195 # 05 Y:1999 | 05 | 1999 | ELIMINATE/REDUCE REDUNDANT INSPECTIONS | $2,496 | $5,000 | Implemented |
HO0195 # 06 Y:1999 | 06 | 1999 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $6,240 | $340 | Not Implemented |
HO0195 # 07 Y:1999 | 07 | 1999 | USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES | $6,192 | $5,000 | Not Implemented |
HO0195 # 08 Y:1999 | 08 | 1999 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $1,248 | $2,500 | Not Implemented |
HO0181 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,163 | $10,944 | Not Implemented |
HO0181 # 02 Y:1998 | 02 | 1998 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $88,443 | $310,000 | Not Implemented |
HO0181 # 03 Y:1998 | 03 | 1998 | INSTALL / REPAIR INSULATION ON STEAM LINES | $532 | $325 | Implemented |
HO0181 # 04 Y:1998 | 04 | 1998 | INSULATE BARE EQUIPMENT | $1,232 | $1,008 | Implemented |
HO0181 # 05 Y:1998 | 05 | 1998 | INSULATE FEEDWATER TANK | $227 | $72 | Implemented |
HO0181 # 06 Y:1998 | 06 | 1998 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $12,922 | $250 | Implemented |
MA0400 # 01 Y:1997 | 01 | 1997 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $347,702 | $505,000 | Not Implemented |
MA0400 # 02 Y:1997 | 02 | 1997 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $17,497 | $92,676 | Not Implemented |
MA0400 # 03 Y:1997 | 03 | 1997 | COVER OPEN TANKS | $15,677 | $6,578 | Implemented |
MA0400 # 04 Y:1997 | 04 | 1997 | INSULATE BARE EQUIPMENT | $605 | $970 | Not Implemented |
MA0400 # 05 Y:1997 | 05 | 1997 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $388 | $0 | Implemented |