Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,436
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0394 # 03 Y:2007 | 03 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,868 | $3,046 | Not Implemented |
SD0394 # 04 Y:2007 | 04 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,578 | $0 | Not Implemented |
SD0394 # 05 Y:2007 | 05 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $302 | $200 | Not Implemented |
LM0123 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,533 | $33,000 | Not Implemented |
LM0123 # 02 Y:2007 | 02 | 2007 | COVER OPEN TANKS | $7,790 | $1,800 | Not Implemented |
LM0123 # 03 Y:2007 | 03 | 2007 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,789 | $20,000 | Not Implemented |
LM0123 # 04 Y:2007 | 04 | 2007 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $37,630 | $1,000 | Not Implemented |
SD0383 # 01 Y:2006 | 01 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $33,958 | $0 | n/a |
SD0383 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,420 | $260 | n/a |
SD0383 # 03 Y:2006 | 03 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $14,249 | $26,550 | n/a |
SD0383 # 04 Y:2006 | 04 | 2006 | DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING | $5,803 | $900 | n/a |
SD0383 # 05 Y:2006 | 05 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,966 | $4,300 | n/a |
SD0383 # 06 Y:2006 | 06 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,957 | $4,270 | n/a |
LM0106 # 01 Y:2006 | 01 | 2006 | COVER OPEN TANKS | $3,315 | $1,500 | Implemented |
LM0106 # 02 Y:2006 | 02 | 2006 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $33,590 | $8,640 | Not Implemented |
SD0375 # 01 Y:2006 | 01 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $16,903 | $13,350 | Implemented |
SD0375 # 02 Y:2006 | 02 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,954 | $7,595 | Not Implemented |
SD0375 # 03 Y:2006 | 03 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $7,356 | $14,145 | Not Implemented |
SD0375 # 04 Y:2006 | 04 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,793 | $3,000 | Implemented |
SD0375 # 05 Y:2006 | 05 | 2006 | INSULATE BARE EQUIPMENT | $6,983 | $537 | Not Implemented |
SD0375 # 06 Y:2006 | 06 | 2006 | INSTALL OCCUPANCY SENSORS | $2,079 | $3,500 | Not Implemented |
SD0375 # 07 Y:2006 | 07 | 2006 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $5,700 | $18,500 | Not Implemented |
SD0375 # 08 Y:2006 | 08 | 2006 | INSTALL EQUIPMENT TO MOVE PRODUCT | $77,126 | $70,000 | Not Implemented |
LM0101 # 01 Y:2005 | 01 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $12,671 | $0 | Not Implemented |
LM0101 # 02 Y:2005 | 02 | 2005 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $200,454 | $75,500 | Not Implemented |