Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
853
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0979 # 05 Y:2017 | 05 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,344 | $2,184 | Not Implemented |
OK0979 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,621 | $42,413 | Not Implemented |
OK0979 # 03 Y:2017 | 03 | 2017 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,833 | $2,600 | Not Implemented |
OK0979 # 02 Y:2017 | 02 | 2017 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $1,410 | $1,400 | Not Implemented |
OK0979 # 01 Y:2017 | 01 | 2017 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $4,648 | $6,600 | Not Implemented |
OK0967 # 01 Y:2017 | 01 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,854 | $3,960 | Not Implemented |
OK0967 # 02 Y:2017 | 02 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,932 | $35,800 | Not Implemented |
OK0967 # 03 Y:2017 | 03 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $776 | $2,508 | Not Implemented |
OK0967 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,303 | $7,634 | Not Implemented |
OK0967 # 05 Y:2017 | 05 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,380 | $6,786 | Not Implemented |
OK0967 # 06 Y:2017 | 06 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,739 | $2,695 | Not Implemented |
OK0967 # 07 Y:2017 | 07 | 2017 | INSTALL SET-BACK TIMERS | $1,719 | $1,020 | Not Implemented |
OK0967 # 08 Y:2017 | 08 | 2017 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $687 | $2,800 | Not Implemented |
OK0967 # 09 Y:2017 | 09 | 2017 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,124 | $30,000 | Not Implemented |
OK0971 # 08 Y:2017 | 08 | 2017 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,433 | $1,608 | Not Implemented |
OK0971 # 05 Y:2017 | 05 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,570 | $10,263 | Implemented |
OK0971 # 01 Y:2017 | 01 | 2017 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $3,220 | $14,212 | Not Implemented |
OK0971 # 02 Y:2017 | 02 | 2017 | RECOVER WASTE HEAT FROM EQUIPMENT | $654 | $1,913 | Not Implemented |
OK0971 # 03 Y:2017 | 03 | 2017 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $199 | $468 | Not Implemented |
OK0971 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,254 | $39,396 | Implemented |
OK0971 # 06 Y:2017 | 06 | 2017 | OPTIMIZE PLANT POWER FACTOR | $19,022 | $4,357 | Not Implemented |
OK0971 # 09 Y:2017 | 09 | 2017 | INSTALL SET-BACK TIMERS | $977 | $1,306 | Implemented |
OK0971 # 07 Y:2017 | 07 | 2017 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $15,676 | $0 | Not Implemented |
OK0970 # 09 Y:2017 | 09 | 2017 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $30,101 | $110,025 | Not Implemented |
OK0970 # 10 Y:2017 | 10 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,002 | $9,779 | Not Implemented |