Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
564
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0537 # 02 Y:2003 | 02 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $6,830 | $10,000 | Not Implemented |
CO0537 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,550 | $32,870 | n/a |
CO0522 # 06 Y:2003 | 06 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $184 | $308 | Not Implemented |
CO0522 # 05 Y:2003 | 05 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $170 | $414 | Not Implemented |
CO0522 # 04 Y:2003 | 04 | 2003 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,870 | $1,950 | Not Implemented |
CO0522 # 03 Y:2003 | 03 | 2003 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $4,300 | $840 | Not Implemented |
CO0522 # 02 Y:2003 | 02 | 2003 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $4,420 | $10,000 | Not Implemented |
CO0522 # 01 Y:2003 | 01 | 2003 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $9,140 | $10,660 | Not Implemented |
CO0508 # 05 Y:2002 | 05 | 2002 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $115,000 | $100,000 | Not Implemented |
CO0508 # 04 Y:2002 | 04 | 2002 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $31,960 | $1,620 | Implemented |
CO0508 # 03 Y:2002 | 03 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,570 | $23,500 | Not Implemented |
CO0508 # 02 Y:2002 | 02 | 2002 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $4,230 | $7,000 | Implemented |
CO0508 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,450 | $90 | Implemented |
CO0505 # 05 Y:2002 | 05 | 2002 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,400 | $1,680 | Not Implemented |
CO0505 # 01 Y:2002 | 01 | 2002 | COVER OPEN TANKS | $18,110 | $30,000 | Not Implemented |
CO0505 # 02 Y:2002 | 02 | 2002 | COVER OPEN TANKS | $11,730 | $15,600 | Not Implemented |
CO0505 # 03 Y:2002 | 03 | 2002 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,940 | $5,400 | Implemented |
CO0505 # 06 Y:2002 | 06 | 2002 | USE OPTIMUM THICKNESS INSULATION | $1,260 | $2,500 | Not Implemented |
CO0505 # 07 Y:2002 | 07 | 2002 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $770 | $60 | Implemented |
CO0505 # 04 Y:2002 | 04 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,800 | $600 | Implemented |
CO0500 # 05 Y:2002 | 05 | 2002 | INSULATE BARE EQUIPMENT | $730 | $300 | Implemented |
CO0500 # 01 Y:2002 | 01 | 2002 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $29,000 | $7,000 | Implemented |
CO0500 # 02 Y:2002 | 02 | 2002 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $8,990 | $300 | Implemented |
CO0500 # 03 Y:2002 | 03 | 2002 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $2,640 | $5,750 | Not Implemented |
CO0500 # 06 Y:2002 | 06 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $290 | $50 | Implemented |