Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,139
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0305 # 01 Y:2001 | 01 | 2001 | INSTALL SKYLIGHTS | $8,175 | $16,112 | Not Implemented |
AS0305 # 02 Y:2001 | 02 | 2001 | INSTALL OCCUPANCY SENSORS | $155 | $225 | Not Implemented |
AS0305 # 03 Y:2001 | 03 | 2001 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,492 | $3,850 | Not Implemented |
AS0305 # 04 Y:2001 | 04 | 2001 | USE SYNTHETIC LUBRICANT | $592 | $277 | Not Implemented |
AS0305 # 05 Y:2001 | 05 | 2001 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $4,588 | $110 | Implemented |
AS0305 # 06 Y:2001 | 06 | 2001 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $14,000 | $1,360 | Implemented |
AS0305 # 07 Y:2001 | 07 | 2001 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $63,963 | $6,820 | Implemented |
UD0630 # 01 Y:2001 | 01 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,607 | $720 | Implemented |
UD0630 # 02 Y:2001 | 02 | 2001 | OPTIMIZE PLANT POWER FACTOR | $11,232 | $5,000 | Implemented |
UD0630 # 03 Y:2001 | 03 | 2001 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $3,449 | $560 | Implemented |
UD0630 # 04 Y:2001 | 04 | 2001 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $3,432 | $700 | Not Implemented |
UD0630 # 05 Y:2001 | 05 | 2001 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $2,639 | $500 | Implemented |
UD0630 # 06 Y:2001 | 06 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,272 | $88 | Implemented |
UD0630 # 07 Y:2001 | 07 | 2001 | INSULATE BARE EQUIPMENT | $611 | $1,180 | Implemented |
UD0630 # 08 Y:2001 | 08 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $300 | $0 | Not Implemented |
AS0304 # 01 Y:2001 | 01 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $895 | $120 | Not Implemented |
AS0304 # 02 Y:2001 | 02 | 2001 | INSTALL SKYLIGHTS | $1,241 | $1,992 | Not Implemented |
AS0304 # 03 Y:2001 | 03 | 2001 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $764 | $2,484 | Not Implemented |
AS0304 # 04 Y:2001 | 04 | 2001 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $5,488 | $648 | Implemented |
AS0304 # 05 Y:2001 | 05 | 2001 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $64,704 | $8,580 | Implemented |
AS0304 # 06 Y:2001 | 06 | 2001 | AUTOMATE FINISHING PROCESS | $58,240 | $688 | Not Implemented |
AS0304 # 07 Y:2001 | 07 | 2001 | DEMOLISH OLD BUILDING TO REDUCE TAX AND INSURANCE BILLS | $29,680 | $438 | Not Implemented |
AS0304 # 08 Y:2001 | 08 | 2001 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $19,493 | $294 | Implemented |
AS0304 # 09 Y:2001 | 09 | 2001 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $16,000 | $3,940 | Implemented |
MA0490 # 01 Y:2001 | 01 | 2001 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $7,248 | $0 | Implemented |